Furuno USA Inc 9ZWFM3000 Manuale Utente

Pagina di 76
9. Troubleshooting
47
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
No power comes ON.
• Bad connection to the power supply.
• Check the connection to the transceiver.
p. 42
No sound comes from
the speaker.
• Squelch level is too high.
• Volume level is too low.
• Speaker has been exposed to water.
• Internal speaker is turned OFF.
• Set squelch to the threshold point.
• Set [VOL] to a suitable level.
• Drain water from the speaker.
• Turn the internal speaker ON in Set mode.
p. 7
p. 7
p. 39
Transmitting is impossi-
ble, or high  power can
er can
-
not be selected.
• Some channels are for low power or re-
ceive only.
• The output power is set to low.
• Change channels.
• Push [HI/LO] to select high power.
pgs.
5, 48
p. 7
Scan does not start.
• ‘TAG’ channel is not prog rammed.
• Set the desired channels as ‘TAG’ chan-
nels.
p. 12
No beep sounds.
• Beep tone is turned OFF.
• The squelch is open.
• Turn the beep tone ON in Set mode.
• Set squelch to the threshold point.
p. 39
p. 7
Receive signal cannot
be understood.
• Optional voice scrambler is turned OFF.
• Scramble code is not set correctly.
• Turn the optional voice scrambler ON.
• Reset the scramble code.
p. 9
p. 40
Sensitivity is low.
• The attenuator is activated.
• Push [LO/DX] to turn the function OFF.
p. 7
Distress call cannot be
transmitted.
• MMSI (DSC self ID) code is not pro-
grammed.
• Program the MMSI (DSC self ID) code.
p. 13