DIGITAL  SELECTIVE  CALLING 
 
13 
 
Sinking, Adrift, Abandoning, Piracy, and MOB (Man Overboard). 
Step 1
 
Open the cover labeled "DISTRESS". 
Step 2
 
Short-press the Distress key.   
The "DISTRESS" screen appears. 
Step 3
 
Select "NATURE". 
The "NATURE" screen appears. 
Step 4
 
Select the nature of the distress. 
Step 5
 
Press and hold the Distress key (about 4 seconds). The unit beeps and 
the display shows the time remaining until the distress signal is sent. 
After the distress signal is sent, the radio waits for an acknowledgement 
with the display showing "AWAIT ACK". 
If no acknowledgement is received, the distress signal is repeated at 3.5-
to-4.5-minute intervals, until a DSC acknowledgement is received.   
Step 6
 
When you receive the DSC acknowledgement, select "ACCEPT". 
Step 7
 
Press and hold the PTT key to announce your situation on CH16. 
Initiate a DSC distress call with manually inputted position 
If no position data is available at the time of distress, you can enter the latitude and 
longitude position of your vessel manually when you send a DSC distress call. 
Step 1
 
Open the cover labeled "DISTRESS". 
Step 2
 
Short-press the Distress key.   
The "DISTRESS" screen appears. 
Step 3
 
Select "POS". 
Step 4
 
Rotate and press the Menu/DSC control to enter the latitude and 
longitude of your vessel and current UTC time in 24-hour format. 
Step 5
 
Press and hold the Distress key (about 4 seconds). The unit beeps and 
the display shows the time remaining until the distress signal is sent. 
After the distress signal is sent, the radio waits for an 
acknowledgement with the display showing "AWAIT ACK". 
If no acknowledgement is received, the distress signal is repeated at 
3.5-to-4.5-minute intervals, until a DSC acknowledgement is 
received.   
Step 6
 
When you receive the DSC acknowledgement, select "ACCEPT". 
Step 7
 
Press and hold the PTT key to announce your situation on CH16. 
Pause a DSC distress call 
After a DSC distress call is sent, the DSC distress call is repeated at 3.5-to-4.5-
minute intervals until the call is canceled by the user, until an acknowledgement is