Furuno USA Inc 9ZWFM4850 Manuale Utente

Pagina di 133
Fog  Horn/Hailer/Intercom 
FM-4850  Operator’s  Manual 
 
46 
 
Sound warning signals   
Warning 
Signal 
 
Function
 
Remarks 
 
Manual   
For ship passing.  The lengths and timing of the horn blasts are 
controlled by pressing and holding the PTT 
key on the handset. 
Yelp 
For emergency 
siren. 
 
Underway   
For power-driven 
vessels 
underway. 
One 5-second blast at 120-second interval. 
 
Stopped   
For power-driven 
vessel that is 
stationary. 
Two 3-second blasts, with a 2-second interval 
between each blast, repeated every 120 
seconds. 
 
Sailboat 
For sailboats, tug 
boats and tow 
boats underway. 
One 3-secondblast, followed by one 2-second 
interval, one 1-second blast, one 2-
secondinterval and one 1-second blast. 
Repeated every 120 seconds. 
5s
120s
Underway
 
Signal
3s
120s
2s 3s
Stopped Signal