Furuno USA Inc 9ZWFM4850 Manuale Utente

Pagina di 133
FM-4850  Operator’s  Manual 
GENERAL  SETUP 
 
61 
 
Step 2
 
Select "OWN UNIT" to view the version of the radio, or select "ALL UNIT" 
to view to view the versions of the radio and connected units. 
Step 3
 
After you view the information, press the Menu/DSC control to return to 
the previous screen. 
10.6.3 
Diagnostic Test 
This feature allows you to test items as shown in the following table. You can also 
see explanations of testing results in the following table. 
Testing Item
 
Explanation of Testing Result
 
GNSS 
OK
: There is a GNSS data source. 
NG
: There is no GNSS data source. 
DSC 
OK
: The DSC feature works normally. 
NG
: The DSC feature doesn't work. 
BATTERY 
OK
: The operating voltage is between 10.8 V DC 
and 15.6 V DC. 
LOW
: The operating voltage is lower than 10.8 V 
DC. 
HIGH
: The operating voltage is higher than 15.6 V 
DC. 
AIS 
OK
: The AIS feature works normally. 
NG
: The AIS feature doesn't work. 
MEMORY 
OK
: The internal memory is normal. 
NG
: The internal memory is abnormal. 
REMOTE STATION 
OK
: Handset is connected to the radio. 
NG
: No handset is connected to the radio. 
 
Step 1
 
In the "SYSTEM INFO" page, select "DIAGNOSTIC TEST". 
The "SYSTEM TEST" page appears on the screen. 
Step 2
 
Select the item requiring testing. 
Step 3
 
Press the Menu/DSC control to start testing. 
Step 4
 
When the test is over, press the Back key to return to the previous 
screen. 
10.6.4 
Factory Reset 
This feature resets several menus and settings to their default values. For details on 
which menu / settings are reset, see the underlined items in the menu tree. 
Step 1
 
In the "FACTORY RESET" page, select “FACTORY RESET”. The 
“FACTORY RESET” page appears on the screen.