Furuno USA Inc 9ZWRTR081A Manuale Utente

Pagina di 155
2. WIRING 
 
2-12
2.3 Transceiver 
Unit 
For FAR-2827W 
Fabricating of RW-9600 
1.  Fabricate the RW-9600 
cable as shown right. 
2.  Trim each wire (except 
coaxial wire) considering its 
location on the terminal 
board. 
4.  Trim the shield leaving 30 
mm and then fold back it. 
5.  Remove insulation of each 
wire by about 6 mm.   
6.  Using the terminal opener, 
insert each core (except 
coaxial cable) to appropriate 
connector plug. 
7.  Insert the coaxial cable to 
the TB802 on TB Board and 
fix the shield with cable 
clamp. 
 
 
 
 
 
Wiring for Coaxial cable
CAUTION
Clamp shied with bracket.
Tighten conductor with screw.
Procedures
1. Twist the conductor.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is ecure.
Terminal opener
Wiring for WAGO connector
WAGO connector
Wire 
Twist
Press downward.
Do not use crimp-on lug to prevent 
contact resistance from increasing.
 
Shield
Fold back shield.
Conductor
6
14 5 9
Coaxial cable
Approx. 250
5
30
Unit: mm
Vinyl sheath
Armor
Shield
Fold back the shield.