2. WIRING 
 
2-29
2.6 
Changing AC Power Specification of Processor 
Unit 
To change AC power specification between 100 VAC and 220 VAC, add or remove jumper 
connector P108 on the PWR board 03P9339 and change the fuse on the processor unit 
according to ship’s mains as shown in the table below. The figure on the next page shows 
the location of the fuse and the jumper connector on the PWR board. Also, adjustment of 
the overvoltage detection circuit is required. 
Note: To change from 220VAC to 100VAC, locally prepare the jumper connector, referring to 
the figure on the next page (VH8P connector housing is fitted at J108). 
 
Power supply  Fuse 
Jumper connector P108 
100 VAC 
10A 
Added 
220 VAC 
5A 
Removed 
Cover of PWR board
Fuse
Upper part of processor unit
(SPU assembly omitted)
PWR board