ICOM 301500 Manuale Utente

Pagina di 102
17
CONNECTING THE  IC-PW1/EURO
To an
antenna
[ACC-1]
[ANT]
[ACC]
[INPUT1]
[REMOTE]
EXCITER
1
1&2
[GND]
[GND]
IC-PW1/EURO
To AC outlet
 Non-European versions : 100–120/220–240 V
 European version   
: 230 V
Ground
Transceiver
[REMOTE]
Remote control cable 
(supplied with the IC-PW1/EURO)
ACC cable 
(supplied with the IC-PW1/EURO)
Coaxial cable
(supplied with the IC-PW1/EURO)
7-pin side
OPC-599 conversion cable
(
)
[ANT]
N Linear amplifier connections
CONNECTING A NON-ICOM LINEAR AMPLIFIER
R WARNING:
•  Set the transceiver output power and linear am-
plifier ALC output level by referring to the linear 
amplifier instruction manual. Be sure the linear 
amplifier keying circuit control voltage is compat-
ible with the IC-7200, before connecting to the 
[SEND] connector.
•  The ALC input level must be in the range +0 V to 
–4 V, and the transceiver does not accept posi-
tive voltage. Non-matched ALC and RF power 
settings could cause a fire or damage the linear 
amplifier.
The IC-7200 SEND line is rated at 16 V/200 mA 
DC. If this level is exceeded, a larger external 
relay must be used.
Transceiver
50 
ø coaxial cable
RF OUTPUT
RF INPUT
ALC
SEND
[ANT]
[ALC]
[SEND]
To an 
antenna
Non-Icom linear amplifier
2