D Auto tuning step function
When rotating the tuning dial rapidly, the tuning
speed accelerates automatically as selected.
speed accelerates automatically as selected.
[DIAL]
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P.AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[M-CH]
q Push and hold
M-CH/RIT
SET
for 1 sec. twice to enter
the set mode.
w Rotate [M-CH] to select “AUTo TS.”
e Rotate [DIAL] to select the desired tuning speed
from HI (High), Lo (Low) and oF (OFF).
• HI : Approx. 5 times faster when the tuning step is set
to 1 kHz or smaller steps; approx. 2 times faster
when the tuning step is set to 5 kHz or larger steps.
when the tuning step is set to 5 kHz or larger steps.
• Lo : Approx. 2 times faster
• oF : Auto tuning step is turned OFF
•
Push and hold
M-CL
for 1 sec. to select a default con-
dition or value.
When “HI” is selected (default)
r Push
M-CH/RIT
SET
to exit the set mode and return to
normal operation.
D ¼ tuning function (SSB data/AM data/CW/RTTY only)
While operating in SSB data/AM data/CW/RTTY, the
¼ tuning function is available for critical tuning. Dial
sensitivity is reduced to ¼ of normal when the ¼
function is in use.
¼ tuning function is available for critical tuning. Dial
sensitivity is reduced to ¼ of normal when the ¼
function is in use.
[DIAL]
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P.AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[M-CH]
q Push and hold
M-CH/RIT
SET
for 1 sec. twice to enter
the set mode.
w Rotate [M-CH] to select “DIAL ¼.”
e Rotate [DIAL] to select the ¼ tuning function ON
and OFF.
•
Push and hold
M-CL
for 1 sec. to select a default con-
dition or value.
When “OFF” is selected (default)
r Push
M-CH/RIT
SET
to exit the set mode and return to
normal operation.
NOTE: This function is only available when the
programmable tuning step is OFF (p. 26).
programmable tuning step is OFF (p. 26).
D Band edge warning beep
When selecting a frequency that lies outside of a
band’s specified frequency range, a warning beep
sounds.
This function can be turned OFF in set mode, if de-
sired.
band’s specified frequency range, a warning beep
sounds.
This function can be turned OFF in set mode, if de-
sired.
[DIAL]
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P.AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[M-CH]
q Push and hold
M-CH/RIT
SET
for 1 sec. twice to enter
the set mode.
w Rotate [M-CH] to select “BAND BEP.”
e Rotate [DIAL] to select the band edge warning
beep function ON and OFF.
•
Push and hold
M-CL
for 1 sec. to select a default con-
dition or value.
When “ON” is selected (default)
r Push
M-CH/RIT
SET
to exit the set mode and return to
normal operation.
3
BASIC OPERATION