ICOM 301500 Manuale Utente
5
44
FUNCTIONS FOR RECEIVE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
N RIT function
The RIT (Receive Incremental Tuning) function com-
pensates for stations transmitting off-frequency or
when you prefer to listen to slightly different-sound-
ing voice characteristics, etc.
The function shifts the receive frequency up to
±9.999 kHz in 1 Hz steps (10 Hz steps when cancel-
ling the 1 Hz step readout) without moving the trans-
mit frequency.
pensates for stations transmitting off-frequency or
when you prefer to listen to slightly different-sound-
ing voice characteristics, etc.
The function shifts the receive frequency up to
±9.999 kHz in 1 Hz steps (10 Hz steps when cancel-
ling the 1 Hz step readout) without moving the trans-
mit frequency.
q Push
RIT
to turn the RIT function ON.
•
“
” and the shift frequency are indicated.
-
The shift frequency is indicated for approx. 1 sec.,
then returns to the operating frequency.
then returns to the operating frequency.
•
The
RIT control indicator lights red.
-
If the RIT control indicator does not light, push
M-CH/RIT
SET
. (See below for details)
w Rotate the [M-CH] control to compensate for off-
frequency stations.
• The transmit frequency is not shifted.
•
The shift frequency is indicated for about 1 sec. when
rotating the [M-CH] control.
rotating the [M-CH] control.
e To cancel the RIT function, push
RIT
again.
•
“
” disappears.
•
The RIT control indicator goes out.
About the [M-CH] control:
The [M-CH] control selects the memory channel
and also shifts the RIT frequency. Pushing
and also shifts the RIT frequency. Pushing
M-CH/RIT
SET
toggles the [M-CH] control as M-CH
selector or RIT controller.
RIT controller: RIT control indicator lights red.
M-CH selector: RIT control indicator goes out.
Shifting frequency
decreases
decreases
Shifting frequency
increases
increases
RIT control indicator
lights red.
lights red.
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P.AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[M-CH]
Appears
• RIT monitor function
When the XFC (transmit frequency check function)
is ON (p. 76), pushing and holding
When the XFC (transmit frequency check function)
is ON (p. 76), pushing and holding
RIT
allows you
to monitor the operating frequency directly (RIT is
temporarily cancelled).
temporarily cancelled).
• Calculate function
The shift frequency of the RIT function can be
added/subtracted to the displayed frequency.
The shift frequency of the RIT function can be
added/subtracted to the displayed frequency.
When the RIT function is ON, push and hold
RIT
*
for 1 sec.
• The RIT frequency is automatically reset.
* Available only when the XFC (transmit frequency check
* Available only when the XFC (transmit frequency check
function) is turned OFF. (p. 76)