ICOM 316800 Manuale Utente

Pagina di 36
26
TROUBLESHOOTING
10
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
The transceiver does not turn 
ON.
• The battery is exhausted.
•  The battery pack is not attached cor-
rectly.
• Recharge the battery pack.
• Attach the battery pack correctly.
p. 23
p. 3
No sound from speaker.
• The squelch level is too high.
• Volume level is too low.
• Speaker has been exposed to water.
• Set the squelch level to the threshold level.
•  Adjust the audio level to a suitable level.
• Drain water from the speaker.
p. 12
p. 11
p. 13
Transmitting  is  impossible, 
or high power can not be se-
lected.
•  Some channels are for low power or re-
ceive only.
• The battery is exhausted.
• The battery is over charged.
• The output power is set to low.
• Change channels.
• Recharge the battery pack.
•  Make sure the battery voltage is correct.
• Push 
[Hi/Lo 
] to select high power.
pgs. 8, 
9, 27
p. 23
p. 10
The displayed channel cannot 
be changed.
• Lock function is activated.
•  Push and hold 
[Hi/Lo 
] for 1 sec. to 
cancel the function.
p. 13
Scan does not start.
• “TAG” channels are not programmed.
•  Set the desired channels as “TAG” chan-
nels.
p. 15
No beep emits.
• Beep tone function is turned OFF.
•  Set the beep tone to ON (Fix Beep/User 
Beep) in the set mode.
p. 18
Battery voltage error.
•  The connected battery pack’s voltage is 
more than 11 V.
•  Make sure the battery voltage is correct.
The noise cancellation does 
not work.
•  The sub-microphone is covered with 
something.
•  An  optional  external  speaker-micro-
phone is connected.
•  Make sure the sub-microphone is not 
covered.
•  Disconnect the microphone.
p. 4
p. 25
The noise detection function 
does not work.
•  The sub-microphone is covered with 
something.
•  The squelch is open.
•  Make sure the sub-microphone is not 
covered.
•  Set the squelch level to the desired level.
p. 4
p. 12