ICOM 325100 Manuale Utente

Pagina di 64
48
11
OTHER FUNCTIONS
Key-touch beep
 
D
Turn the confi rmation beeps ON (default) or OFF.
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Time-out timer
 
D
To prevent accidental prolonged transmission, the 
transceiver has a time-out timer. The function inhibits 
continuous transmissions longer than the set time pe-
riod (1–30 minutes).
• TOT-OF 
: Turns OFF the function. (default)
• TOT-1–30 
:  The transmission is cut OFF after the 
set time period ends. 
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Auto repeater
 
D
 
U.S.A. version only
The Auto Repeater function automatically turns the 
duplex setting and tone encoder ON or OFF when 
the operating frequency falls within or outside of the 
general repeater output frequency range (145.200–
145.495 MHz, 146.610–146.995 MHz and 147.000–
147.395 MHz). 
The offset and repeater tone frequencies are not 
changed by the Auto Repeater function; reset these 
frequencies, if necessary.
• OF  : The Auto Repeater function is OFF.
• R1  : Activates for duplex only. (default)
• R2  : Activates for duplex and tone.
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Auto power OFF
 
D
The transceiver can be automatically turned OFF, when 
no key operation is performed for the specifi ed time pe-
riod. 30 min., 1 hour, 2 hours and OFF (default) are se-
lectable. 
The time period is retained, even if the transceiver is 
turned OFF by the auto power OFF function. To cancel 
the function, select “OF” (OFF).
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO
AO
BUSY
MUTE
NAR
MID
LOW
Repeater lockout
 
D
Set the transmission lockout (temporary transmission 
inhibit) capability.
• OF  : No lockout is activated. (default)
• RP  : The repeater lockout is turned ON.
• BU  : The busy lockout is turned ON.
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Busy lock-out setting
Repeater lock-out setting
Squelch delay
 
D
Set the squelch delay to short or long. The delay pre-
vents the squelch from repeatedly opening and closing, 
while receiving the same signal.
• S  : Short squelch delay. (default)
• L 
: Long squelch delay.
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Short squelch delay setting
Long squelch delay setting
Squelch type
 
D
Set the squelch type to OFF (Noise squelch), S-meter 
Squelch or Squelch Attenuator.
• OF  : Noise squelch (default)
• SS  : S-meter squelch
    
 
 
The S-meter squelch allows you to set a mini-
mum signal level needed to open the squelch.
    
 
Rotate [SQL] to adjust the S-meter squelch lev-
el. The S-meter is automatically activated when 
[SQL] is rotated further than the 12 o'clock posi-
tion.
• AT  : Squelch Attenuator
    
 
 
The attenuator is automatically activated when 
[SQL] is rotated further than the 12 o'clock posi-
tion. Approximately 20 dB of attenuation is ob-
tained at the maximum setting.
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO
MUTE
NAR
MID
LOW
S-meter squelch
Noise squelch (default)