ICOM 375410 Manuale Utente

Pagina di 68
22
3
BASIC OPERATION
3
201802
201802
BASIC MANUAL
 
D
Sweep operation
Example: Continuous sweeps centered on 146.010 MHz
1.  Push [VFO/MR] to select the VFO mode.
2.   Rotate [DIAL] to set 146.010 MHz.
3.  Push [SCOPE].
4.   Select “Continuous Sweep.” 
(Rotate [DIAL] to select, and then push [ENTER].)
 •Returns to the frequency display and starts the 
continuous sweep.
5.  Push [CLEAR].
 •Stops the sweep.
6.  Rotate [DIAL] to move the sweep marker to a 
detected signal.
 •You can hear the signal audio.
 
L
Pushing [SCOPE] and then selecting “Center Recall” 
returns the sweep marker to the center frequency.
7.  Push [SCOPE].
8.   Select “Scope OFF,” and then push [ENTER].
 •Turns OFF the Band Scope function.
Sweeping
After stopping 
the sweep, move 
the marker to a 
detected signal.
TIP:
 •If the tuning step is set too wide, the signals in the sweep range may not be displayed 
(they may be skipped), even if they are strong signals. Therefore, we recommend that 
you set the tuning step to 20 kHz or less to use the Band Scope function.
 •During a sweep the frequency range of 108.000 ~ 520.000 MHz, the displayed 
frequency’s audio is output. (When the receive mode is set to WFM, LSB, USB, CW or 
CW-R, the audio is not output.) 
You can turn OFF the audio output on the MENU screen. 
([MENU] > Sounds > 
Scope AF Output)
[SCOPE]