ICOM IC-703 Manuale Utente

Pagina di 112
72
11
CONTROL COMMAND
D
Command table
Command
Sub command
Description
00
Send frequency data
01
Same as 
Send mode data
command 06
02
Read band edge frequencies
03
Read operating frequency
04
Read operating mode
05
Set operating frequency 
06
00
Select LSB
01
Select USB
02
Select AM
03
Select CW
04
Select RTTY
05
Select FM
07
Select CW-R
08
Select RTTY-R
07
Select VFO mode
00
Select VFO A
01
Select VFO B
A0
Equalize VFO A and VFO B
B0
Exchange VFO A and VFO B
08
Select memory mode
0001–0105*
Select memory channel
*1A=0100, 3b=0105
09
Memory write
0A
Memory to VFO
0B
Memory clear
0E
00
Scan stop
01
Programmed/memory scan start
0F
00
Turn the split function OFF
01
Turn the split function ON
10
00
Select 10 Hz (1 Hz) tuning step
01
Select 100 Hz tuning step
02
Select 1 kHz tuning step
03
Select 5 kHz tuning step
04
Select 9 kHz tuning step
05
Select 10 kHz tuning step
06
Select 12.5 kHz tuning step
07
Select 20 kHz tuning step
08
Select 25 kHz tuning step
09
Select 100 kHz tuning step
11
Select/read attenuator (00=OFF,
20=ON (20 dB))
13
00
Announce with voice synthesizer
01
(00=all data; 01=frequency and 
02
S-meter level; 02=operating mode)
14
01 + Level data
[AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data
[RF] level setting (0=max. CCW to
255=11 o’clock)
03 + Level data
[SQL] level setting (0=11 o’clock to
255=max. CW)
04 + Level data
[IF SHIFT] position setting (0=max.
CCW; 128=center; 255=max. CW)
06 + Level data
Noise reduction level setting
(0=min. to 255=max.)
07 + Level data
Twin PBT (inside) setting (0=max.
CCW, 128=center, 255=max. CW)
08 + Level data
Twin PBT (outside ) setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data
CW pitch setting (0=300 Hz,
128=600 Hz, 255=900 Hz)
Command
Sub command
Description
14
0A + Level data
RF power setting (0=mini. to
255=max.)
0B + Level data
Microphone gain setting (0=mini.
to 255=max.)
0C + Level data Key speed setting (0=slow to
255=fast)
0E + Level data
COMP Level setting (0=0 to 10=10)
0F + Level data
Break-IN DELAY setting (20=2.0d
to 130=13.0d)
15
01
Read squelch condition
02
Read S-meter level
11
Read RF power meter 
12
Read  SWR meter 
13
Read ALC meter 
16
02
Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
12
AGC selection (1=Fast; 2=Slow)
22
Noise blanker (0=OFF; 1=ON)
40
Noise reduction (0=OFF; 1=ON)
41
Auto notch (0=OFF; 1=ON)
42
Subaudible tone (0=OFF; 1=ON)
43
Tone squelch (0=OFF; 1=ON)
44
Speech compressor (0=OFF; 1=ON)
45
Monitor (0=OFF; 1=ON)
46
VOX function (0=OFF; 1=ON)
47
Break-in (0=OFF; 1=semi break-
in; 2=full break-in)
19
00
Read the transceiver ID
1A
00
Send/read memory contents
01
Send/read band stacking register
contents (see p. 73 for details)
02
Send/read memory keyer con-
tents (see p. 73 for details)
0301
Send/read beep emission set
(0=OFF, 1=ON)
0302
Send/read band edge beep set
(0=OFF, 1=ON)
0303
Send/read beep output level set
(0=min. to 255=max.)
0304
Send/read beep limit set (0=OFF,
1=ON)
0305
Send/read CW carrier point set
(0=LSB, 1=USB)
0306
Send/read CW side tone level set
(0=min. to 255=max.)
0307
Send/read CW side tone limit set
(0=OFF, 1=ON)
0308
Send/read 9600 bps mode set
(0=OFF, 1=ON)
0309
Send/read VOX gain set (0=min.
to 255=max.)
0310
Send/read anti VOX gain set
(0=min. to 255=max.)
0311
Send/read VOX delay time set
(0=0 sec. to 20=2.0 sec.)
0312
Send/read meter selection
(0=Power, 1=SWR, 3=ALC)
0313
Send/read SSB carrier frequency
(00=–200 Hz to  40=200 Hz;
10 Hz steps)
CW: Clockwise, CCW: Counter Clockwise
11