ELAD srl ART120 Manuale Utente

Pagina di 15
ELAD DUO-ART 120 
 
User Manual - Rev. 1.1 - 04/2018 
 
© 2018 ELAD S.r.l. All rights reserved. No part of this document may be reproduced, published, used, disclosed or disseminated 
 in any form or by any means, electronic, photocopying or otherwise, without prior written permission of ELAD S.r.l.
 
 
3  User Interface 
3.1 
Main View 
When the DUO-ART 120 is started the main view is displayed. The main view is divided in five horizontal 
sections. The top one shows a graph with the current transmission power and transmission frequency. 
The second section is a status bar that includes information about the current settings. The third section 
is a diagnostic bar that shows some diagnostic information. The fourth section is used to show warnings. 
The last section is the menu bar which is composed of six choice corresponding to the six push-buttons. 
The first one and the last one have an long-press option to open other views. 
 
 
 
The configurations are saved in memory banks, and it’s possible to switch between them pressing the 
“MEM” button. The banks can be added or deleted until a maximum of 20 banks.  The two underlined 
button (MEM and VIEW) have a second function if pressed longer. 
 
The “IN-ATT” button allows to choose the Stand-by mode and to set the input attenuators value (0, 2, 3 
and 5 dB). 
 
The “ANT” button allows to choose the antenna connector used to transmit. 
 
The “TUNE” button allows to enter in the tune menu.  
 
The “SET” button allows to enter in the settings menu.  
 
The “VIEW” button allows to change the displayed graphic : 
View 1 : forward power and reflected power, 
View 2 : forward power and SWR, 
View 3 : forward power and input power, 
View 4 and 5 : spectrum view.