Talgil Computing and Control LTD RF-MODULE-45 Manuale Utente

Pagina di 34
 
32
 
 
The display is refreshed each scanning cycle. 
 
The  drawings  of  the  LEDS  on  the  left  side  indicate  the  status  of 
communication  with  each  of  the  RF  SLAVES  (or  with  each  RTU).  An  RTU, 
which  responds  properly,  will  be  indicated  by  a  LED  lighting  constantly.  An 
RTU  that  did  not  respond  the  call  of  the  MASTER  will  be  indicated  by  a 
blinking LED. The RTUs that were not called by the MASTER either because 
they  are  undefined  or  because  the  call  of  the  MASTER  was  not  received 
remain dark.  
 
On  the  right  side  of  the  window  appear  rows  of  characters  that  describe  the 
information transmitted either by the MASTER or by one of the SLAVES. The 
rows are shifted downward with each new row received by the RF EAR. 
 
The following r
ow contains information about the MASTER’s transmission : 
 
      
00:01:05(852)   M->X    (04)02   00000000(00)   TD   AA RSSI=66 
 
 
 
 
 
 
 
 
 
 
 
The response of the slave has the following format: 
 
00:01:05(901)   M<-X    (04)02   00000010(02)   NT   OK RSSI=66 
 
 
 
 
 
 
 
 
 
Notice that in the 8 bits string containing the status of the outputs or the inputs 
the rightmost digit represents the lower Output/Input bit. 
 
When an RTU is defined to communicate through a REPEATER, there will be 
4  rows  describing  the  process:  1)  the  call  of  the  MASTER; 2)  the transfer of 
the call to the SLAVE by the REPEATER; 3) the response of the SLAVE and 
4) the transfer of the response to the MASTER by the REPEATER.  
The time at which 
the communication 
took place..
 
The brackets 
contain 
milliseconds. 
 
M – > X indicates 
a call from  the 
MASTER to 
SLAVE - X  
 
The number  of the 
SLAVE -X is 2. 
The number in 
brackets is the 
selected frequency 
channel. 
 
The status of the 
outputs-each bit 
represents 1 out of 
8 outputs. “0” 
means closed, “1” 
means open.
 
The  RSSI indicates 
the  strength of the 
MASTER’S signal:
 
For GIII:
 
41-73 = Strong
 
34-40 = Medium
 
20-33 = Low
 
M <– X indicates 
the response from  
SLAVE - X  to the 
MASTER. 
 
The status of the 
inputs-each bit 
represents 1 out of 
4 outputs.
 
 “0” means open 
contact, “1” means 
closed contact.
 
The  RSSI indicates 
the  strength of the 
SLAVE’S signal:
 
For GIII:
 
41-73 = Strong
 
34-40 = Medium
 
20-33 = Low