Invenco Group Ltd G6OPT Manuale Utente
DCV-00001 Rev 05 S2 G6 OPT Installation Guide
Page 14
4.4 Replacement of a G5 Product
The G6 OPT is designed to fit into the existing cut-out created for the G5 OPT to allow an
easy upgrade.
To simplify this process a Retrofit Kit is available for either side-mounting or top/bottom-
mounting, depending on the model of G5 OPT being replaced.
Before beginning, determine whether the existing G5 OPT is:
To simplify this process a Retrofit Kit is available for either side-mounting or top/bottom-
mounting, depending on the model of G5 OPT being replaced.
Before beginning, determine whether the existing G5 OPT is:
side-mounted (with a motorised card reader), or
top/bottom-mounted (with a manual card reader).
4.4.1 Power Supply Considerations
The G5 OPT was typically installed with one of the following power supplies:
Meanwell S-100-24
Franmar S-100F-24
Either of these power supplies is quite capable of driving a single G6 OPT.
Some installations may have used a single supply to drive two G5 OPTs, in which case care
needs to be paid to the maximum internal temperature of the enclosure, to avoid the power
supply becoming overloaded after de-rating for temperature.
The G6 OPT draws considerably more power than the older terminals and while two terminals
will likely operate from a single supply, Invenco does not guarantee error-free operation.
needs to be paid to the maximum internal temperature of the enclosure, to avoid the power
supply becoming overloaded after de-rating for temperature.
The G6 OPT draws considerably more power than the older terminals and while two terminals
will likely operate from a single supply, Invenco does not guarantee error-free operation.
De-rating curves for typical G5 OPT (left) and recommended G6 OPT (right) power supplies.