DB ELETTRONICA TELECOMUNICAZIONI S.P.A. MOZART500 Manuale Utente

Pagina di 87
 
 
22 /87
4.2
 
CONNECTIONS 
 
Install the transmitter so that the space over and under the equipment is sufficient for the cooling air 
to flow through. 
Before installing the equipment always make sure that the transmitter is not powered. This has the 
purpose to prevent electrical shocks to the operators and damage to the equipment. 
Before carrying out any other electrical connection, connect the rack to the station ground. 
 
 
Connect the transmitting antenna cable or the  cable related to the connection of the output 
filter to the output connector of the unit (in the latest case connect the output of the filter to 
the transmitting antenna) using a 50 Ohms coaxial cable. 
 
In case the transmitter is not connected to an external control unit, check that the ENABLE 
connector on the back panel is correctly inserted. 
 
Connect  the  power  cord  to  an  operating  source.  Make  sure  that  the  power  supply  source 
provides the nominal voltage prescribed. 
 
Note: the unit is designed to operate with the nominal voltage ±15%. We suggest the installation of 
spike  suppressors,  line  conditioners,  isolation  transformers,  AVR  and/or  UPS  or  other  devices 
useful to protect the equipment from eventual damages that can be caused by the mains fluctuations.