REMOTE I/O (OPTIONAL) 
 
 
The  Remote  I/O  is  an  optional  interface  that  provides  the  DB25  connector  REMOTE  to  monitor 
and control the unit through digital signals. The signals available are: 
 
 
 
 
Pin 
Name 
I/O 
Function 
TC_1 
Tele Command 
TC_3 
Tele Command 
OFF 
TC_5 
Tele Command 
Change to MEMORY 0 
TC_7 
Tele Command 
Change to MEMORY 2 
TC_9 
Tele Command 
Change to MEMORY 4 
TC_11 
Tele Command 
VCC_FIELD 
Vcc 
+12V 
TS_11_TM4 
Tele Signal 
ON 
TS_9_TM2 
Tele Signal 
LOCAL 
10 
TS_7/OUT_ANA7 
Tele Signal 
AUDIO_OK 
11 
TS_5/OUT_ANA5 
Tele Signal 
MEMORY 1 
12 
TS_3/OUT_ANA3 
Tele Signal 
MEMORY 3 
13 
TS_1/OUT_ANA1 
Tele Signal 
MEMORY 5 
14 
TC_2 
Tele Command 
ON 
15 
TC_4 
Tele Command 
RESET 
16 
TC_6 
Tele Command 
Change to MEMORY 1 
17 
TC_8 
Tele Command 
Change to MEMORY 3 
18 
TC_10 
Tele Command 
Change to MEMORY 5 
19 
GND_OUT 
GND 
GND 
20 
TS_COM 
COMMON 
Tele Signals Common 
21 
TS_10_TM3 
Tele Signal 
NO_FAULT 
22 
TS_8_TM1/OUT_ANA8 
Tele Signal 
RF_OK 
23 
TS_6/OUT_ANA6 
Tele Signal 
MEMORY 0 
24 
TS_4/OUT_ANA4 
Tele Signal 
MEMORY 2 
25 
TS_2/OUT_ANA2 
Tele Signal 
MEMORY 4 
 
Table 7.1 – Remote I/O pinout 
 
The particular unit state is verified if there is a short-circuit between the relative Tele Signal pin and 
the Common pin (pin 20). 
To  send  a  command  to  the  unit  (only  in  remote  state)  is  necessary  a  short-circuit  between  the 
particular Tele Command pin and GND for at least 100ms.