DB ELETTRONICA TELECOMUNICAZIONI S.P.A. MOZART500 Manuale Utente

Pagina di 87
 
 
76 /87
8.2
 
UPGRADING PROCEDURES 
 
 
8.2.1
 
UPGRADING THE MODULATOR FIRMWARE 
 
The modulator firmware upgrade is available only with the webserver board installed.  
The  copies  of  modulator  firmwares  are  always  stored  in  the  webserver  board  so  it  is  possible  the 
downgrade in case of failed upgrading attempts. 
 
To start the procedure please follow these points: 
 
1.
 
Power on the unit maintaining pressed the OK key to start the unit in bootloader mode. 
 
 
Fig. 8.9 – Start in bootloader mode 
 
2.
 
 Connect  a  PC  to  the  unit  using  a  crossover  LAN  cable.  Open  a  browser  and  type  the  IP 
address  of  the  unit.  Usually  the  boot  time  of  webserver  loading  is  1  minute,  after  that  the 
webpage will be active. 
3.
 
Login as administrator. 
4.
 
Go  to  the  “Modulator  Upgrade”  menu  and  press  the  “Sfoglia”  button  to  select  the  new 
firmware. 
 
Fig. 8.10 – Modulator Upgrade page