testo Instruments Co. Ltd 056001550 Manuale Utente

Pagina di 19
8 Tips and assistance 
18 
Tips and assistance 
 
8.1. 
Questions and answers 
 
Question Possible 
causes/solution 
 flashes 
Batteries are almost empty. 
> Change 
batteries. 
The instrument switches 
off automatically. 
Residual capacity of the batteries is 
too low. 
> Change 
batteries. 
uuuu
 lights up instead of 
the parameter display 
 
The permissible measuring range has 
been undershot. 
>  Keep to the permitted measuring 
range. 
oooo
 lights up instead of 
the parameter display 
 
The permissible measuring range has 
been exceeded. 
>  Keep to the permitted measuring 
range. 
 
 
8.2. 
Measurement parameters 
Name Description 
Δtoh SH 
Superheating, 
evaporation pressure 
Δtcu
 
SC 
Subcooling, condensation pressure 
to 
Ev 
Refrigerant evaporation temperature 
tc 
Co 
Refrigerant condensation temperature 
toh T1 
Measured 
temperature, evaporation 
tcu 
T2 
Measured temperature, condensation