RF Engineering & Energy Resource LLC KI-GSM904 Manuale Utente

Pagina di 21
10
19.New password setting
User can modify the system with new password in the case of forgetting the
previous password
Command:[*]→[7]→[A]→[A]→[*]
A= new password with 4 digits .The defaulted password is 0000
Example: We need to modify the new password to 8585, we can press command
[*]→[7]→[8585]→[8585]→[*] on the main panel
20.System reset
All data will be cleared, except for coded sensors
Command:[*]→[8]→[A]→[*]
A= password, default password: 0000
Example: Press command [*]→[8]→[0000]→[*], the system will be reset
21.Record setting
User can record 10 seconds voice to show alarm information including
address, telephone number etc, which will be played on the alarm call
Command:[*]→[0]→[A]→[*]
A= system password
Example:Press command [*]→[0]→[0000]→[*] on the main panel firstly, and say
something within 10 seconds near to panel about 20cm. It will quit automatically when
time’s out
22.System time setting
Before installation, user can set the correct time for the system as per the
following command
Command:[*]→[0]→[7]→[A]→[B]→[C]→[D]→[E]→[*]
A= Year, 15 means 2015, 16 means 2016
B=Month, 01 means Jan, 10 means Oct
C=Day,11 means 11
th
,08 means 08
th,
D=Hour, 08 means 8 o’clock, 09 means 9 o’clock
E=Minute, 05 means 5 minute, 20 means 20 minute
Example, Set system time to 2016 years at 12:25 on Oct 13
th,
user can press the
command [*]→[0]→[7]→[16]→[10]→[13]→[12]→[25]→[*]
Note: The system time will be clear if the system was off, so please switch on the battery
for system in case of ac power failure
23.Timely arm setting
System supports max 5 groups of timely arm, it will be armed automatically
everyday as per the time
Command: [#]→[0]→[7]→[A]→[B]→[C]→[#]
A=Hour, 08 means 8 o’clock, 09 means 9 o’clock
B=Minute, 30 means 30 minutes, 20 means 20 minutes
C=Group number, max 5 groups