Nokia Shanghai Bell Co. Ltd. A240ZA Manuale Utente
26 3FE-46615-AAAA-TCZZA
Issue:
01
ETSI environmental and CRoHS guidelines
7368 ISAM CPE A-240Z-A Product Guide
3.3 Other environmental requirements
Observe the following environmental requirements when handling the P-OLT or CPE
equipment.
equipment.
3.3.1 CPE environmental requirements
See the CPE technical specification documentation for more information about
temperature ranges.
temperature ranges.
3.3.2 Storage
According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in
Class 1.1, weather-protected, temperature-controlled locations.
Class 1.1, weather-protected, temperature-controlled locations.
3.3.3 Transportation
According to EN 300-019-1-2 - Class 2.3, transportation of the OLT equipment must
be in packed, public transportation with no rain on packing allowed.
be in packed, public transportation with no rain on packing allowed.
3.3.4 Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of OLT equipment
must be in a temperature-controlled location, with no rain allowed, and with no
condensation allowed.
must be in a temperature-controlled location, with no rain allowed, and with no
condensation allowed.
3.3.5 Thermal limitations
When the OLT is installed in the CO or CEV, install air filters on the P-OLT. The
thermal limitations for OLT operation in a CO or CEV are:
thermal limitations for OLT operation in a CO or CEV are:
•
operating temperature: 5
C to 40C (41F to 104F)
•
short-term temperature: –5
C to 50C (23F to 122F)
•
operating relative humidity: 5% to 85%
•
short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg