ANSI CPE safety guidelines
7368 ISAM CPE A-240Z-A Product Guide
34 3FE-46615-AAAA-TCZZA
Issue: 
01
 
 
 
During installation and maintenance, service personnel must wear wrist straps to 
prevent damage caused by ESD. 
Nokia recommends that you prepare the site before you install the CPE equipment. 
In addition, you must control relative humidity, use static dissipating material for 
furniture or flooring, and restrict the use of air conditioning. 
 
4.5 Environmental 
requirements 
 
See the CPE technical specification documentation for temperature ranges for 
CPEs. 
During operation in the supported temperature range, condensation inside the CPE 
caused by humidity is not an issue. To avoid condensation caused by rapid changes 
in temperature and humidity, Nokia recommends: 
• 
The door of the CPE not be opened until temperature inside and outside the 
enclosure has stabilized. 
• 
If the door of the CPE must be opened after a rapid change in temperature or 
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of 
condensation. 
• 
When high humidity is present, installation of a cover or tent over the CPE helps 
prevent condensation when the door is opened.