IBM HS22V 7871H2U Dépliant

Codici prodotto
7871H2U
Pagina di 1
IBM
Type-model
Processor 
Watts
L3
cache 
GHz
1
Memory 
Core
Ethernet
Available
date
I/O slots 
Disk
controller
Disk 
bays
Mechanical
LIMITED WARRANTY
3
(HS 22VA) ��IBM C orp. February 2011
S ee footnotes for important warranty information
IBM BladeCenter
 HS22V
xREF by STG Field Skills and Education Team
Maximum internal disk capacity for each HS22V blade server
13
: 100GB with two 50GB SSD disks
3 year parts and labor
International Warranty Service
3
On site, 8 am-5 pm,
Mon-Fri excluding holidays,
next business day response time
On site service upgrade 
options (in eligible locations):
7
4 year IOR 9x5, NBD response
(ServicePac
 part num 69P 9520)
4 year IOR 9x5, 4 hr avg response
(ServicePac part num 69P 9521)
4 year IOR 24x7, 4 hr avg response
(ServicePac part num 69P 9522)
4 year IOR 24x7, 2 hr avg response
(ServicePac part num 69P 9523)
Other ServicePac options at 
http://www.ibm.com/services/us/its/pdf/
wamomxeu.pdf
Positioning
Two-socket, high performance blade server optimized for virtualization
P rocessor(s) 
Up to two Next Generation Intel
��
Xeon featuring Quick Path Interconnect(QPI) at up to 3.46GHz with up to 12MB L3 /
up to 6 Core / with Intel Turbo Boost Technology and Hyper-Threading
L3 cache 
4 or 12MB  std and max / at processor speed
S MP
2-way SMP / up to two Xeon P rocessors (same speed/cache size)
Implementation
Systemboard contains two Socket B (LGA1366) sockets, eighteen DIMM slots, one High Speed Daughter Card connector,
one I/O expansion option connector, integrated graphics and dual Gigabit ethernet ports
Memory
6GB std / 
144GB max per processor(
using 16GB DIMMs)
PC3-10600 1333MHz VLP 240-pin ECC DDR3 SDRAM 
DIMMs / eighteen slots on base blade / ChipKill / memory mirroring
Disk C ontroller
LSI Logic
��
1064E SAS controller / four port / 300MB/sec / on planar / 64-bit P CI-Express / supports RAID-0 & 1 / 
Disks 
Two Solid State Disk (SSD) connectors / supports 1.8" non-hot swap SSD disks 
Flash Storage
Dedicated USB-based slot on systemboard for optional Hypervisor USB key
External Storage
Support for IBM TotalStorage� solutions
Mechanical
Single slot blade / Supported in IBM BladeCenter E, S, H and HT
Architecture/Chipset
Intel 5520 chipset / Intel IO Hub provides P CI-Express bridge to: ICH10 South Bridge, High Speed Daughter Card
connector and Legacy Daughter Card connector(CIOv), BCM5709S dual GbE, LS I 1064E SAS / 
ICH10 South Bridge provides: USB, P CI-Express and LP C bus to VSC452 for video and limited Super I/O
BUS slots
No P CI or P CI-X slots (expansion via modules or network-interface option connector)
Ethernet
Dual Gigabit Ethernet ports / Broadcom
 5709S / two full gigabit ethernet MAC and P HY  layer functions / integrated /
P CI-Express / full duplex / TCP /IP  Offload Engine (TOE) / Wake on LAN
/ iSCSI / Serial over LAN / P XE 2.0 / 
Failover, adapter fault tolerance / Load balancing / one of the dual controllers connects to an optional, supported 
Ethernet switch or 
Passthrough Module (the second controller requires a second optional switch or PM)
Network Interface
One legacy connector or PCI-Express connector for I/O expansion options / requires same interface modules in bays 3 and 4 
of BladeCenter / all blades in a single BladeCenter must contain the same expansion card (or no expansion card)
Optical / diskette / USB
None / requests for optical, diskette and USB port in BladeCenter by pressing media select button on front control panel
Kybd / video / mouse
None / requests for keyboard, video and mouse in BladeCenter by pressing the display button on front control panel
Graphics controller
SVGA / Matrox
 G200e integrated in IMM on systemboard / 16MB DDR2-250MHz SDRAM std/max / 32-bit 33MHzP CI 2.2
Systems Mgmt
Integrated Management Module(IMM) / VSC452 / H8S2461 / integrated / provides system and environmental 
monitoring, event recording, alert capability / TP M 1.2 / ASR / SOL / IP MI 2.0 / RS-485 interface for intermanagement 
communication with BladeCenter Management module / remote supervision and cKVM standard
Diagnostics
Light Path Diagnostics� (LED lights indicate failing component) and on-board diagnostics
Security
No security intrusion protection / Trusted P latform Module(TP M) / Power-on password / administrator password / 
unattended boot / selectable boot / unattended start mode
Software ship group
Documentation CD, Broadcom CD, ServerGuide CD
Cooling
Uses cooling from BladeCenter /  thermal sensors on
each processor, BladeCenter modules and front panel
Power supply(s)
Uses power module(s) in BladeCenter chassis
P rerequisites
Monitor, keyboard, mouse for setup; ethernet switch 
module, disk, BladeC enter chassis, operating system
Xeon E5540 2.53GHz 80W 5.86Ts P roc Upg
49Y 5163
Xeon X5570 2.93GHz 95W 6.4GTs P roc Upg
49Y 5172
Xeon E5506 2.13GHz 80W 6.4GTs P roc Upg
49Y 5151
Xeon X5677 3.46GHz 130W 6.4GTs P roc Upg
69Y 4747
Xeon X5680 3.33GHz 130W 6.4GTs P roc Upg
69Y 4748
1GB (1x1GB) P C3-10600 CL9 ECC DDR 3 1333MHz VLP  RDIMM
44T1485
2GB (1x2GB) P C3-10600 CL9 ECC DDR 3 1333MHz VLP  RDIMM
44T1487
4GB (1x4GB) P C3-10600 CL9 ECC DDR 3 1333MHz VLP  RDIMM
44T1488
8GB (1x8GB) P C3-8500 CL7 ECC DDR3 1066MHz VLP  RDIMM
44T1579
IBM 50GB SSD 1.8" 
43W7734
SAS Connectivity Card for IBM BladeCenter
43W4068
Ethernet Expansion Card for IBM BladeC enter
44W4475
Virtual Fabric Adapter
49Y 4235
IBM USB Memory Key for VMware Hypervisor ESXi 3.5 U4
41Y 8269
IBM USB Memory Key for VMware Hypervisor ESXi 4.0
41Y 8278
Other  options at 
ibm.com/products/us
3x2GB
3x2GB
3x1GB
3x1GB
3x2GB
3x2GB
3x2GB
3x2GB
3x2GB
3x2GB
3x2GB
3x2GB
6x4GB
6x2GB
3x2GB
3x2GB
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Mar 2010
Aug 2010
Aug 2010
 2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
2 x Gb
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
single slot blade
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
up to 2
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
S AS
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
8MB
8MB
4MB
4MB
12MB
12MB
12MB
12MB
12MB
12MB
12MB
12MB
12MB
12MB
12MB
12MB
80W
95W
80W
80W
80W
80W
95W
95W
95W
60W
95W
80W
95W
80W
130W
130W
1 x Xeon
  E 5540
1 x Xeon    X5570
1 x Xeon    E 5507
1 x Xeon    E 5503
1 x Xeon    E 5620
1 x Xeon    E 5640
1 x Xeon    X5650
1 x Xeon    X5670
1 x Xeon    X5667
1 x Xeon    L5640
1 x Xeon    X5650
1 x Xeon    E 5640
1 x Xeon    X5660
1 x Xeon    E 5640
1 x Xeon    X5680
1 x Xeon    X5677
2.53
2.93
2.26
2.0
2.40
2.66
2.66
2.93
3.06
2.26
2.66
2.66
2.80
2.66
3.33
3.46
4C
4C
4C
2C
4C
4C
6C
6C
4C
6C
6C
4C
4C
4C
6C
4C
7871-B4x
7871-C 4x
7871-A4x
7871-D3x
7871-G2x
7871-G4x
7871-H2x
7871-H4x
7871-H5x
7871-N2x
7871-HAx
7871-GDx
7871-E Hx
7871-E Gx
7871-F 2x
7871-F 3x
Stealth black front bezel
H 9.7" x W 1.14" x D 17.6";
H 24.5cm x W 2.9cm x D 44.6cm 
12 lbs; 5.4kg (max configuration)
Configuration/Setup Utility: F1 at startup
Diagnostics: F2 at startup
System Partition Boot: ALT+F1 at startup
Network Boot: F12 at startup
P XE Boot Agent Utility: Ctrl+S at startup
Blade control panel on each HS22 blade server provides
media select button, kbd/mouse/video select button and LEDs
P redictive Failure Analysis
alerts on memory, 
processor(s) and disk(s) with IBM Director
 connector for non-hot swap, optional 1.8" solid state disk
 connector for non-hot swap, optional 1.8" solid state disk
Front control panel LEDs: Power, Activity, Location,Information and Fault
Server blade
(side view)
blade expansion 
connector
opt
C P U
daughter card
connector
std
C P U

DIMM slot 9
/\
:
:
:
:
"
DIMM slot 1
DIMM slot 10
"
:
:
:
:
\/
DIMM slot 18