Fan modules
The Enterprise Chassis supports up to a total of ten hot-swap fan modules: two 40 mm (1.57 in) fan 
modules and eight 80 mm (3.14 in) fan modules.
The two 40 mm fan modules distribute airflow to the I/O modules and chassis management modules. 
Both of these fan modules ship with the chassis. The 80 mm fan modules distribute airflow to the compute 
nodes through the chassis from front to rear. Each 80 mm fan module actually contains two 80 mm fan 
modules, back to back at each end of the module, which are counter-rotating. The following figure shows 
the 80 mm fan module.
Figure 12. 80 mm  fan module
Four 80 mm fan modules are installed standard in chassis model 8721-A1x. The maximum number of 80 
mm fan modules that can be installed is eight. Ordering information is shown in the following table. When 
the modules are ordered as a part number or feature code, they are supplied as a pair.
Table 9. Fan module ordering information
Description
Part number System x
Feature code
Power 
Systems
Feature code
IBM Flex System Enterprise Chassis 80mm Fan Module Pair (2 
fan modules)
43W9078
A0UA
7805
The 80 mm fan modules are populated, depending on the nodes installed. To support the base 
configuration and up to four nodes, chassis model 8721-A1x ships with four 80 mm fan modules and two 
40 mm fan modules preinstalled. There are two cooling zones for the nodes: a left zone and a right zone. 
Fan modules must be installed in pairs as shown in the following figure. If there are insufficient fan 
modules for the number of nodes installed, the compute nodes might be throttled to balance heat 
generation and cooling capacity.