Alcatel-Lucent OS6850EP24X-EU Manuale Utente
Alcatel-Lucent OmniSwitch 6850E | Data Sheet
3
Technical Specifications
Physical dimensions
• Chassis size without PS and shelf:
¬ Width: 44.0 cm (17.32 in.)
¬ Depth: 27.0 cm (10.63 in.)
¬ Height: 4.4 cm (1.73 in.)
¬ Depth: 27.0 cm (10.63 in.)
¬ Height: 4.4 cm (1.73 in.)
• Total size including PS and shelf:
¬ Width: 48.2 cm (19.00 in.)
¬ Depth: 44.6 cm (17.56 in.)
¬ Height: 4.4 cm (1.73 in.)
¬ Depth: 44.6 cm (17.56 in.)
¬ Height: 4.4 cm (1.73 in.)
Indicators
• Per-port LEDs
¬ RJ-45: PoE, link/activity
¬ SFP: link/activity
¬ SFP+: link/activity
¬ SFP: link/activity
¬ SFP+: link/activity
• System LEDs
¬ Switch ID (indicates the stack ID
of the unit in the stack)
¬ PRI (virtual chassis primary)
¬ System (OK) (chassis HW/SW
¬ System (OK) (chassis HW/SW
status)
¬ PWR (primary power supply
status)
¬ BPS (backup power status)
Acoustic levels
• Under 48 dB for all models, mea-
sured with a single power supply
at room temperature
Environmental requirements
• Operating temperature: 0°C to
+45°C (+32°F to +113°F)
• Storage temperature: -10°C to
+70°C (+14°F to +158°F)
• Humidity (operating and storage):
5% to 95% non-condensing
Cyclic temperature and humid-
ity tests of -5°C to +55°C, 5% to
90% Relative Humidity (RH) for
the duration of ~185 hours as per
GR-63-CORE
Interface and speeds
• 24 and 48 ports 10/100/1000, 24
ports 100/1000Base-X
• Modular 2x 10Gig SFP+ uplinks
• Wire rate at layer 2 and layer 3 on
• Wire rate at layer 2 and layer 3 on
all ports
• Switching throughput numbers
per models (with the optional
uplinks):
¬ OS6850E-48/-P48 (48 GigE
¬ OS6850E-48/-P48 (48 GigE
ports + 2 x 10G): 101.2 Mp/s
¬ OS6850-48X/-P48X (48 GigE
ports + 4 x 10G): 131 Mp/s
¬ OS6850-24/-P24 (24 GigE ports
+ 2 x 10G): 65.5 Mp/s
¬ OS6850-24X/-P24X (24 GigE
ports + 4 x 10G): 95.3 Mp/s
¬ OS6850-U24X (24 GigE ports +
4 x 10G): 95.3 Mp/s
Compliance
and certifications
and certifications
Commercial
EMI/EMC
• FCC CRF Title 47 Subpart B (Class A)
• VCCI (Class A)
• AS/NZS 3548 (Class A)
• CE marking for European coun-
• VCCI (Class A)
• AS/NZS 3548 (Class A)
• CE marking for European coun-
tries (Class A)
• EN 55022:2006+A1:2007 (EMI &
EMC )
• EN 61000-3-2:2006
• EN 61000-3-3:1995 +A2:2005
• EN 55024:1998 +A1:2001
• EN 61000-3-3:1995 +A2:2005
• EN 55024:1998 +A1:2001
+A2:2003 (Immunity)
¬ EN 61000-4-2: 2001
¬ EN 61000-4-3:2002
¬ EN 61000-4-4:2004
¬ EN 61000-4-5:2001
¬ EN 61000-4-6:2004
¬ EN 61000-4-8:2001
¬ EN 61000-4-11:2004
¬ EN 61000-4-2: 2001
¬ EN 61000-4-3:2002
¬ EN 61000-4-4:2004
¬ EN 61000-4-5:2001
¬ EN 61000-4-6:2004
¬ EN 61000-4-8:2001
¬ EN 61000-4-11:2004
• IEEE802.3: Hi-Pot Test (2250 V DC
on all Ethernet ports)
Safety agency certifications
• US UL 60950
• IEC 60950-1:2006+A11:2009
• IEC 60950-1:2006+A11:2009
Electric/Health and Safety
• CAN/CSA-C22.2 No. 60950-1-03
• NOM-019 SCFI, Mexico
• AS/NZ TS-001 and 60950:2000,
• NOM-019 SCFI, Mexico
• AS/NZ TS-001 and 60950:2000,
Australia
• UL-AR, Argentina
• UL-GS Mark, Germany
• EN 60825-1 Laser:
• UL-GS Mark, Germany
• EN 60825-1 Laser:
1993+A1:1997+A2:2001
• EN 60825-2 Laser:2004
• CDRH Laser
• CDRH Laser
• IEC 60950-1/EN 60950 with all
country deviations. IEC 60950
1:2005, Second Edtion
* Note: Class A with UTP cables.
Detailed product
features
features
Simplified manageability
Management interfaces
• Intuitive, familiar Alcatel-Lucent
operating system (AOS) which
is modular by design and com-
mon to all OmniSwitch families,
reduces training costs and TCO
• Easy to use, point-and-click,
web-based element manager
(WebView) with built-in help for
easy configuration
• Integrated with Alcatel-Lucent
OmniVista™ products for net-
work management
• Full configuration and report-
ing using SNMPv1/2/3 across all
OmniSwitch families to facilitate
third-party network management
system integration
• Remote switch access using
Telnet or Secure Shell (SSH)
• File upload using USB, TFTP, FTP,
SFTP, or SCP for faster configura-
tion
• Human-readable ASCII-based
configuration files for off-line
editing, bulk configuration and
out-of-the-box auto-provisioning
Monitoring and
troubleshooting
• Local (on the flash) and remote
server logging: Syslog and com-
mand log
• Port based mirroring for trouble-
shooting and lawful interception;
supports four sessions with mul-
tiple sources-to-one destination
• Policy based mirroring allows
selection of the type of traffic to
mirror by using QoS policies
• Remote port mirroring facilitates
passing mirrored traffic through
the network to a remotely con-
nected device
• Port monitoring feature allows
capture of Ethernet packets to a
file to assist in troubleshooting
• Flow v5 and RMON for advanced
monitoring and reporting
capabilities for statistics, history,
alarms and events
• IP tools: ping and trace route
• ITU-T Y.1731 and IEEE 802.1ag
• ITU-T Y.1731 and IEEE 802.1ag
Ethernet OA&M: Connectivity
Fault Management and perfor-
mance measurements (layer-2
ping and link trace)
• IEEE 802.3ah Ethernet in the First
Mile (EFM) for link monitoring,
remote fault detection, and
loopback control (layer-1 ping)
• Unidirectional Link Detection
(UDLD) detects and disables
unidirectional links on fiber optic
interfaces
• Digital Diagnostic Monitoring
(DDM): Real-time diagnostics of
fiber connections for early detec-
tion of optical signal deterioration
• Link Monitoring: link flap detec-
tion and link error counts to
identify bad connections and
automatically make adjustments
to use the links that are good
Table 3. OmniSwitch 6850E power consumption, heat dissipation, MTBF and weights
PRODUCT
MTBF (HOURS)
POWER CONSUMP-
TION (WATTS)*
TION (WATTS)*
HEAT DISSIPATION
(BTU/HOUR)**
(BTU/HOUR)**
WEIGHTS
(CHASSIS ONLy)
(CHASSIS ONLy)
PoE MODELS
OS6850E-P24
186206
84
287
3.88
OS6850E-P24X
178085
94
321
3.91
OS6850E-P48
168662
150
512
4.2
OS6850E-P48X
161769
152
519
4.21
NON-PoE MODELS
OS6850E-24
272970
58
198
3.79
OS6850E-24X
270735
66
225
3.81
OS6850E-48
253153
91
311
3.95
OS6850E-48X
242611
102
348
3.97
OS6850E-U24X
290159
56
191
3.77
*Calculated maximum power consumption. The power consumed by the power device attached to the PoE port
is not included.
** Under full traffic load