Altronix AL600ULACM Dépliant

Pagina di 2
AL600ULACM
• Eight (8) independently controlled
fuse protected outputs.
AL600ULACMCB
• Eight (8) independently controlled
PTC protected outputs.
• Class 2 Rated power limited outputs.
• The AL600ULACM / AL600ULACMCB converts an 115VAC 60Hz input 
into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or 
Fail-Secure outputs with a total of 6 amp continuous supply current. These 
power outputs can be converted to dry form "C" contacts (AL600ULACM 
only). Outputs are activated by an open collector sink or normally open (NO) 
dry trigger input from an Access Control System, Card Reader, Keypad, Push 
Button, PIR, etc. These units will route power to a variety of access control 
hardware devices including Mag Locks, Electric Strikes, Magnetic Door 
Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure 
modes. The units are designed to be powered by one common power source 
(factory installed) which will provide power for both the board operation and 
locking devices, or two (2) totally independent power sources, one (1) 
providing power for board operation and the other for lock / accessory power. 
The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be
used to trigger other auxiliary devices. The fire alarm disconnect feature is 
individually selectable for any or all of the eight (8) outputs.
• 12VDC or 24VDC @ 6 amp supply current.
• Power supply input options: 
a) One (1) common power input for ACM8/ 
ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs - One (1) to power 
the ACM8/ACM8CB and one (1) for lock 
accessory power, (external power supply 
is required). (Current is determined by the 
power supply connected, not to exceed a 
maximum of 10 amp total).
• Eight (8) Access Control System trigger inputs.
Input options:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
• Eight (8) independently controlled outputs.
Output options:
a) Eight (8) Fail-Safe and/or Fail-Secure 
power outputs.
b) Eight (8) form “C” 5 amp rated relay outputs 
(AL600ULACM only).
c) Any combination of the above 
(AL600ULACM only).
• Eight (8) auxiliary power outputs (unswitched) 
• Output ratings:
- Fuses are rated @ 3.5 amp (AL600ULACM).
- PTCs are rated @ 2.5 amp (AL600ULACMCB).
• ACM8 board main fuse is rated at 10 amp.
• Input 115VAC 60Hz rated @ 1.9 amp.
• Filtered and electronically regulated outputs 
(built-in power supply)
• Red LEDs indicate outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is 
individually selectable for any or all of the 
eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) 
dry contact input.
b) Polarity reversal input from FACP
signaling circuit.
• Alarm output relay indicates that FACP input 
is triggered (form “C” contact rated @ 1 amp 28VDC
not evaluated by UL).
• Green LED indicates when FACP disconnect 
is triggered.
• Built-in charger for sealed lead acid or gel type batteries.
• AL600ULXB (Power Supply Board) 
maximum charge current .7 amp.  
• Automatic switch over to stand-by battery 
when AC fails.
• AC input and DC output LED indicators.
• Zero voltage drop when unit switches over to battery 
backup (AC failure condition).
• Short circuit and thermal overload protection. 
• AC fail supervision (form "C" contact). 
• Battery fail and battery presence supervision 
(form "C" contact).
• Enclosure accommodates up to two (2) 12AH batteries.
• Product weight: 
- AL600ULACM: 10.3 lbs.
- AL600ULACMCB: 10.2 lbs.
• Shipping weight: 
- AL600ULACM: 11.6 lbs.
- AL600ULACMCB: 11.5 lbs.
AL600ULACM, AL600ULACMCB 
Power Supply/Chargers w/Multi-Output 
Access Power Controllers            
Rev. DSAL600ULACM - A25F
Overview
Specifications