IBM x440 Compute Node 7917D2G Manuale Utente

Codici prodotto
7917D2G
Pagina di 33
IBM Flex System x440 Compute Node
25
Figure 9. Location of x440 light path diagnostics panel
To illuminate the light path diagnostics LEDs, power off the compute node, slide it out of the chassis, and 
press the power button. The power button doubles as the light path diagnostics remind button when the 
server is removed from the chassis. The meanings of the LEDs are listed in the following table.
Table 16. Light path diagnostic panel LEDs
LED
Meaning 
LP
The light path diagnostics panel is operational.
S BRD
A system board error is detected.
MIS
A mismatch has occurred between the processors, DIMMs, or HDDs.
NMI
A non-maskable interrupt (NMI) has occurred.
TEMP
An over-temperature condition occurred that was critical enough to shut down the server.
MEM
A memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit. 
ADJ
A fault is detected in the adjacent expansion unit (if installed).