Transition Networks SISTF1010-150-LR(T) Manuale Utente

Pagina di 39
SISTF1010-150-LR(T)  Industrial Unmanaged Switch
 
Transition Networks 
24-Hour Technical Support:   1-800-260-1312   International: 00-1-952-941-7600
 
13 
Connecting power to the Industrial Switch, continued 
 
Note: 
The terminal block can accept 12 – 24 AWG wire for power and alarm relay inputs. 
 
Terminal-block 
wiring 
To wire the 6-position terminal block for redundant power, do the following: 
Note: 
The 6-position terminal-block plug is constructed (keyed) to mate with the Industrial 
Switch terminal block.  When wiring the plug for power, use the polarity markings next 
to the terminal block and on top of the plug to ensure proper connection. 
 
Step 
Action 
1. 
 
Turn the external power source OFF. 
2. 
 
Strip the power wires as required. 
3. 
 
Insert one stripped power wire into the terminal block plug.  Observe polarity. 
See Figure 9. 
4. 
 
Secure the wire using a flathead screwdriver by tightening the contact screw. 
See Figure 9. 
5. 
 
Repeat Steps 3 and 4 until all wires are installed and secured. 
 
 
 
Figure 9:  6-Position Terminal-Block (Primary/Redundant Power Wiring) 
 
Continued on next page