Tripp Lite RV1012UL Manuale Utente

Pagina di 14
In
ver
ter/Char
g
er DC 
V
olt:
12
Wire Gaug
e
Twin 00 (2/0)
W
atts
6
4
2
0
00 (2/0)
(R
V2012OEM, R
V2512OEM & R
V3012OEM
only)
500
15 ft
25 ft
39 ft
62 ft
79 ft
158 ft.
700
11
 ft
18 ft
28 ft
44 ft
56 ft
11
2 ft.
1000
N/R
12 ft
20 ft
31 ft
39 ft
78 ft.
2000
N/R
N/R
N/R
16 ft
20 ft
40 ft.
2400
N/R
N/R
N/R
13 ft
16 ft
32 ft.
3000
N/R
N/R
N/R
10 ft
13 ft
26 ft.
† 
N/R = Not Recommended. NOTE: 
Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the
 performance)
2R
Limited W
arranty
T
ripp Lite w
arr
ants its In
ve
rter/Chargers to be free from def
ects in mater
ials and w
o
rkmanship f
or a 30 month per
iod from the d
ate of retail purchase b
y
 end user
.
T
ripp Lite’
s ob
ligation under this w
arr
anty is limited to repair
ing or replacing (at its sole option) an
y such def
ectiv
e produc
ts
.
T
o obtain ser
vice under this w
arr
ant
y
y
ou m
ust obtain a Retur
ned Mater
ial A
uthor
ization (RMA) n
u
mber from 
T
ripp Lite or an au
thor
iz
ed T
ripp 
Lite
ser
vice center
.
Products m
ust be retur
ned to 
T
ripp Lite
o
a
n
 author
iz
ed 
T
ripp Lite ser
vice center with tr
anspor
tation charges prepaid and m
ust be accompanied b
y
 a br
ief descr
iption of the 
prob
lem encountered and
proof of date and place of purchase
.
This w
arr
anty
does not apply to equipment which has been damaged b
y
 accident, 
negligence or misapplication or has 
been
altered or modified in 
an
y w
a
y,
 including opening of the unit’
s casing f
or an
y reason.
This w
arr
anty applies only to the or
iginal purchaser who m
ust ha
ve
proper
ly registered the product within 10 da
ys of retail purchase
.
EXCEPT AS PR
O
VIDED HEREIN, 
TRIPP LITE MAKES NO 
W
ARRANTIES
, EXPRESS OR IMPLIED
, INCLUDING 
W
ARRANTIES OF MERCHANT
ABILITY AND FITN
ESS FOR A P
A
R
TICULAR PURPOSE.
Some states do not per
mit limitation or e
xclusion of implied
w
arr
anties;
theref
ore
, the af
oresaid limitation(s) or e
xclusion(s) ma
y not apply to the purchaser
.
EXCEPT AS PR
O
VIDED ABO
VE, IN NO EVENT 
WILL 
TRIPP LITE BE LIABLE FOR DIRECT
, INDIRECT
, SPECIAL, INCIDENT
AL OR CONSEQ
UENTIAL D
AMA
GES ARISING OUT OF 
THE USE OF 
THIS PR
ODUCT
, EVEN IF AD
VISED OF 
THE POSSIBILITY
OF SUCH D
AMA
GE.
Specifically
T
ripp Lite is not liab
le f
or an
y costs
, such as lost profits or re
v
e
n
u
e
, loss of equipment, loss o
f use of equipment, loss of softw
are
, loss of data, costs of substitutes
, claims b
y
 third par
ties
, or otherwise
.
T
ripp Lite has a policy of contin
uous impro
v
ement.
Specifications are subject to change without notice
.
Note on Labeling  
T
w
o symbols are used on the R
V
 labels.
V~
:
A
V
olta
g
e
    
V
:
DC V
olta
g
e
Minimum Recommended Cable Sizing Chart
Use in conjunction with DC wiring connection instructions in the Battery Connection section.
Specifications
MODEL NUMBER:
R
V612UL
R
V612ULH
R
V1012UL
R
V1012ULHW
R
V1512UL
R
V2012UL
R
V2012OEM
R
V2512OEM
R
V3012OEM
Ser
ies Number
:
A
GAP60012MVJ
A
GAP60012MVJ
A
GAP100012MV3
A
GAP100012MV3
A
GAP200012MV3
A
GAP200012MV3
A
GAP200012MVP3
A
GAP4669
Agency Appro
v
als:
UL458
UL458
UL458 with Mar
ine Sup
.
UL458
UL458
UL458 with Mar
ine Sup
.
UL458
None
UL458
A
Input Connection:
Input Cord
Hardwire
Input Cord
Hardwire
Hardwire
Hardwire
Hardwire
Hardwire
Hardwire
INVER
TER
Common Specifications f
or All Models:
DC Input 
V
olts (Nominal):
12 
VDC • · DC Input 
V
oltage Range:
10 - 15 
VDC • Output 
V
olts (Nominal):
120 
V
A
, ± 5% • Output F
requenc
y (Nominal):
60 Hz, ± 0.5% • Efficiency:
88% to 94%, depending on load and temper
ature
Select 
T
ripp Lite In
ver
ter/Char
g
e
rs
 inc
lude a Batter
y
 Char
g
e
 Conser
ver (Load Sense) Contr
ol whic
h sa
ves batter
y
 po
wer b
y
 allo
wi
ng user
s to set the minim
um load le
vel 
at 
whic
the 
unit’
s
in
ver
ter turns on.
User
s can significantl
y reduce the No Load DC Input Current (appr
o
ximatel
y 1 to 3 A f
or all models) to a ver
y
 lo
w amp le
vel with the use of this contr
ol.
Contin
uous P
o
w
er (@ 20 C):
600
600
1000
1000
1500
2000
2000
2500
3000
Ov
erP
o
w
er™ P
eak Surge P
o
w
e
r:
*
9
0
0
9
0
0
1500
1500
2250
3000
3000
3750
4500
Doub
le Boost™ P
eak Surge P
o
w
e
r:
*
1200
1200
2000
2000
3000
4000
4000
5000
6000
Maxim
um Output A
 Current 
5 A
5
 A
8.3 A
8.3 A
12.5 A
16.7 A
16.7 A
20 A
25 A
(Contin
uous):
UL Required DC Fuse 
TPN-80 (fuse)
TPN-80 (fuse)
ANL-200 (fuse)
ANL-200 (fuse)
ANL-275
tw
o ANL-200 (fuse)
tw
o ANL-200 (fuses)
tw
o ANL-200 (fuses)
tw
o ANL-27
5 (fuses)
and Fuse Bloc
k:
R25100-1CR (fuse b
loc
k)
R25100-1CR (fuse b
loc
k)
4164 (fuse b
loc
k)
4164
(fuse b
loc
k)
4164
(fuse b
loc
k)
4164
(fuse b
loc
k)
tw
o
 4164
(fuse b
loc
ks)
tw
o 4164 (fuse b
loc
ks)
tw
o 4164 (fuse b
loc
ks)
(or equiv
alent)
Bussmann 
Bussmann
Bussmann
Busmann
Bussmann
Bussmann
Bussmann
Bussmann 
Bussmann 
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
(man
uf
acturer)
DC Input Current @ 
Nominal V 
DC 
Full Load:
56 A
56 A
95 A
95 A
145 A
190 A
190 A
240 A
290 A
B
A
TTER
Y CHARGER
Common Specifications f
or All Models •
Acceptance 
V
olts 
VDC:
Selectab
le 14.4 
V** / 14.2 
W
et** / Gel • Float 
V
olts DC (w/gel):
13.3 
V (13.6 
V) • · Input 
V
olts (Nominal
):
120 V
A
Charging Capacity DC:
45 A / 11 A**
45 A** / 11 A
55 A** / 14 A
55 A** / 14 A
75 A** / 19 A
100 A** / 25 A
100 A** / 25 A
120 A** / 30 
A
140 A** / 35 A
Input Current A
:
9.5 A
9.5 A
11.5 A
11.5 A
15 A
20 A
20 A
24 A
30 A
LINE V
A
OPERA
TION
Common Specifications f
or All Models  •
Input F
requency (Nominal):
60 Hz, ±10%
Maxim
um Input 
V
o
lts (T
ransf
er to Batter
y) (Contin
uous
, Charger at Maxim
u
m):
Selectab
le 135** or 145 
V
A
Minim
um Input 
V
olts:
Selectab
le 95** or 
Selectab
le 95** or
Selectab
le 75**, 85, 
Selectab
le 75**, 85, 
Selectab
le 75**, 85, 
Selecta
b
le 75**, 85, 
Selectab
le 75**, 85, 
Selectab
le 75**, 85, 
Selectab
le 75**, 85, 
(T
ransf
er to Batter
y)
105 
V
A
1
05 
V
A
95 or 105 
V
A
95 or 105 
V
A
95 or 105 
V
A
9
5 or 105 
V
A
95 or 105 
V
A
95 or 105 
V
A
95 or 105 
V
A
Maxim
um Input A
 Current 
11.3 A
14.5 A
12 A
20 A
35 A
38 A
40 A
44 A
37 A
(Contin
uous
, Charger 
at Maxim
um):
Maxim
um Bypass A
Current:
6
 A
6
 A
12 A
12 A
20 A
20 A
20/20 A
20/20 A
20/20 A
(Load circuit break
er limited)
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). 
Actual duration depends on battery age, battery c
harge level and ambient temperature. **Factory setting. 
The policy of 
Tripp Lite is one of continuous improvement. Specificatio
ns are subject to change without notice. 
This product designed and engineered in the USA.
W
ARRANTY REGISTRA
TION
Visit www
.tr
ipplite
.com/w
arr
anty to 
register the w
arr
anty of y
our ne
T
ripp Lite product.
ou'll be automatically
entered into a dr
a
wing f
or a chance to
win a FREE 
T
ripp Lite product!*
* No purchase necessar
y.
V
oid where prohibited.
Some restr
ictions apply
.
See w
ebsite f
or details
.
200502023 RV Series Inverter-Charger Owner’s Manual.qxd  3/7/2005  7:42 PM  Page 2