Tripp Lite TM500 Manuale Utente

Pagina di 3
SYSTEM OVERVIEW
Voltage compatibility
120V AC
Frequency
compatibility
60Hz
OUTPUT
Output VA
500
Output watts
300
Output nominal
voltage
120V AC
Output voltage
regulation
LINE MODE: Passes line voltage from 100-145V to connected equipment unchanged. 
BATTERY MODE: PWM sine wave output 120V +/-5%
Output frequency
regulation
LINE MODE: Passes line frequency of 60Hz +/-10% 
BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Outlet quantity / type
6 NEMA 5-15R
INPUT
Input connection
type
NEMA 5-15P
Input cord length
6 ft.
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime
6 minutes (500VA)
Half load runtime
17 minutes (250VA)
DC system voltage
12V DC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge rate
2-4 hours to 90%
LEDS ALARMS & SWITCHES
Front panel LEDs
Front panel LEDs indicate line power status, battery power status and battery low/replace status
Alarms
Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front
panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain.
Switches
Includes 6 front panel switches — one main on/off power switch and one dual function "alarm cancel" / "self test" button,
plus 4 switches to control individual output receptacles
SURGE / NOISE SUPPRESSION
AC surge
suppression
480 joules
AC suppression
response time
Instantaneous
Dataline suppression
Tel/DSL
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Shipping weight (lbs)
17
Shipping weight (kg)
7.7
Unit weight (lbs)
14.4
Unit weight (kg)
6.5
Unit Dimensions
(HWD/in)
2 x 13.5 x 12.5