STEP 2 - Fit a 3-wide hinge brace to the top of the array and a 3-wide rear brace to the 
bottom of the array using the twelve M10 x 40mm hex screws provided and torque to 25Nm. 
The use of thread-locking compound is recommended (see Appendix). Fit an M10 eyebolt to 
the centre of the rear brace. 
 
 
STEP 3 – Fit the enclosure connector to the top of the array. 
Locate the four M10 eyebolts from the fixings kit supplied and insert these through the 
enclosure connector into the rigging points on the centre cabinet. These will be used to pick 