Hafler DH-200 Manuale Utente

Pagina di 21
The power transformer supplied in DH-220 amplifiers sold in
the lJSA is intended for 120 volt, 60 Hz operation only. For use
in other countries, a multi-voltage transformer is available at
higher cost. It has dual tapped primary windings which can be
arranged in various series-parallel combinations for 100, 110,
120, 200, 220 and 240 volt 50 or 60 cycle AC mains. The
schematic diagram details the wiring combinations which are
represented  pictorially here.
Note that a separate 2-lug terminal strip is required when the
multi-voltage transformer is used. This is supplied in kits which
include the special transformer. If the amplifier is operated with
200  to 240 volt tines, the 7 amp line fuse which is supplied should
be replaced with a 4 amp Slo-Blo  type fuse.
VOLTAGE CHART
measured  with 120 volt line, no signal. with respect to the ground buss between the two capacitors in the power supply.
E B c E B c s  G D
Ql
62.6 62.1) 0.88 
Q 8
63.0 62.0 1.54 Q401 0 1.0
65.4
Q2
-62.6 -62.0 -0.37 
Q9
-1.27 -0.6 1.54 Q402
0 1.0 65.4
Q3 -0.32 0.22 
61.8 
QlO
-63.0 -62.0 0 Q403 0 -0.8 -65.4
Q4
-0.32 0.22 61.8 
Q11
-63.0 -62.0 -1.35 Q404 0 -0.8 -65.4
Q 5
0.8 0.22 -62.0 Ql2
1.0 1.54
65.0
Q6
0.8 0.22 -62.0 Q13 -0.8 -1.35 -65.0
Q7 63.0 62.0 0
12