Honeywell ADEMCO LYNXR Series Manuale Utente

Pagina di 72
 
–29– 
56 Enhanced Zone Programming Mode 
 
 
 
 
RF Learning - Two (2) transmissions (2 key depressions) at least 5 
seconds apart  will be required for BR type devices (device type 5). Two 
beeps will sound after the second transmission, confirming that the loop 
number and serial number have been learned. 
For all other device types, four (4) transmissions are required (fault, 
restore and fault, restore). A single beep will sound after the second 
transmission confirming that the loop and serial number have been 
captured. Following the fourth transmission the system will confirm that 
the loop number and serial number have been learned and announce the 
Voice Descriptor for the zone, if it is programmed, followed by two beeps.  
Press [
] to continue. 
Manual Entry - Enter the desired loop number and press [
] to 
continue (see the transmitter’s Installation Instructions for specific loop 
designations). 
Note:  The loop number can be changed even if the zone has already 
been entered. Care should be taken when using this feature as it 
has the capability to make zones inoperable by creating a 
mismatch of a working serial number/loop number combination. 
This should be re-confirmed if the loop number is changed. 
 
 “L” indicates that the zone’s serial number has already been enrolled. 
 
 
 
F
 
 
Delete zone parameters 
confirmation
 
0 = discard the delete request 
1 = confirm requested delete 
 
Note:  If 00 was entered as a zone type in prompt 
(b), 00 will be retained and system will 
advance to prompt (1C) 
This function deletes either the serial number  or all zone information 
that is programmed for the zone. 
If  “00” was entered in the zone type, the confirmation of the delete 
request will delete all information associated with the zone currently 
being programmed. 
 
If  “0” was entered in the loop number, the confirmation of the delete 
request will delete the serial number of to the zone currently being 
programmed. 
 
 
 IA
 
LC
 
Enroll mode 
0 = advance to the VOICE DESCRIPTOR 
prompt (1C).  
Note:  This will save all zone parameters. 
 
1 = enter now and proceed to SERIAL 
NUMBER prompt (1b). 
Note:  Not applicable if the serial number is 
already present. 
 
2 = copy the last serial number entered into 
local ram. 
 
Note:  If this is the 1st zone, none will be in the 
buffer and the panel will emit a long tone. 
Not valid if serial number is already present. 
 
3 = view existing serial number. 
Note:  Only if “
L” is displayed. If “L” is not 
displayed, panel will emit a long beep. 
 
9 = advance to F; delete existing serial 
number. 
Note:  Only if “
L” is displayed. If “L” is not 
displayed, panel will emit a long beep. 
 
 
[✻] = advance to the VOICE DESCRIPTOR 
prompt (1C). This will save all zone 
parameters. 
 
[#] = return to the LOOP NUMBER prompt 
(E). 
 
Note:  In order for all entered parameters to be 
accepted, you must advance to the VOICE 
DESCRIPTOR prompt (1C). 
 
If “L” is displayed, the serial number for this transmitter has already 
been entered. It may, however, still be viewed, confirmed (only if in 
listen mode), or deleted. 
 
View serial number  
Enter “3”. Each digit will be redisplayed, and the keypad will beep once 
for digits 1-6, and three times for the last digit. 
 
Confirm serial number 
The serial number/loop number combination can be confirmed after one 
transmission from a BR type device or two transmissions (fault and 
restore) from a UR or RF type device. If a transmission is received that 
matches the serial number and loop number entered, the system will 
confirm the reception by announcing the Voice Descriptor for the zone, if 
it is programmed, followed by three beeps, and a “C” will appear on the 
display indicating the received serial number and loop number have 
been confirmed. No further transmissions will be received. 
 
Delete serial number 
The serial number can be deleted by entering “9”. 
 
If “L” is not displayed, the serial number for this transmitter has not 
been previously entered. You may enter the serial number manually, 
copy the previous serial number, return to Prompt (E) or enter the serial 
number later using the 
83 Enhanced Sequential Mode. 
 
 