Reliance Water Heaters N71120NE Manuale Utente

Pagina di 56
12
water temperature control and mixing ValVes
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting devices such as
mixing valves must be installed
when required by codes and to
ensure safe temperatures at fixtures.
Water  heated  to  a  temperature  which  will  satisfy  clothes 
washing, dish washing, and other sanitizing needs can scald 
and  cause  permanent  injury  upon  contact.  Short  repeated 
heating  cycles  caused  by  small  hot  water  uses  can  cause 
temperatures at the point of use to exceed the water heater’s 
temperature setting by up to 20°f (11°C).
Some people are more likely to be permanently injured by 
hot water than others. These include the elderly, children, the 
infirm  and  the  physically/mentally  disabled.  Table  6  shows 
the  approximate  time-to-burn  relationship  for  normal  adult 
skin. If anyone using hot water provided by the water heater 
being installed fits into one of these groups or if there is a 
local code or state law requiring a certain water temperature 
at the point of use, then special precautions must be taken.
In addition to using the lowest possible temperature setting 
that satisfies the demand of the application a mixing Valve 
should be installed at the water heater (see figure 10) or at the 
hot water taps to further reduce system water temperature.
mixing valves are available at plumbing supply stores. Consult 
a qualified Installer or Service Agency. follow mixing valve 
manufacturer’s instructions for installation of the valves.
table 6.
Water Temperature
Time to Produce 2nd & 3rd
Degree Burns on Adult Skin
180°f (82°C)
Nearly instantaneous
170°f (77°C)
Nearly instantaneous
160°f (71°C)
About 1/2 second
150°f (66°C)
About 1-1/2 seconds
140°f (60°C)
Less than 5 seconds
130°f (54°C)
About 30 seconds
120°f (49°C)
More than 5 minutes
gas pressure reQuirements
All  models  require  a  minimum  gas  supply  pressure  of  5.2” 
W.C.  The  minimum  supply  pressure  is  measured  while  gas 
is  not  flowing  (static  pressure)  AND  while  gas  is  flowing 
(dynamic pressure). The supply pressure (static and dynamic) 
should never fall below 5.2” W.C. The supply pressure should 
be  measured  with  all  gas  fired  appliances  connected  to  the 
common  main  firing  at  full  capacity.  If  the  supply  pressure 
drops more than 1.5” W.C. as gas begins to flow to the water 
heater then the supply gas system including the gas line and/
or  the  gas  regulator  may  be  restricted  or  undersized.  See 
Supply gas regulator section and gas Piping section of this 
manual. The low gas pressure switch will shut down the water 
heater  if  the  supply  gas  pressure  drops  below  the  minimum 
allowable value.
The  gas  valve  on  all  models  has  a  maximum  gas  supply 
pressure  limit  of  14"  W.C.  If  a  supply  gas  regulator  is 
installed on the gas supply line, the maximum recommended 
pressure  for  the  regulated  gas  supply  is  11"  W.C.  The 
maximum  supply  pressure  is  measured  while  gas  is  not 
flowing (static pressure) AND while gas is flowing (dynamic 
pressure).
supply gas regulator
The  water  heater  covered  by  this  manual  may  require  the 
installation of a supply gas regulator. If the supply gas pressure 
exceeds 14 inches W.C. a supply gas regulator must be used. 
If  the  gas  supply  pressure  exceeds  14"  W.C.  in  a  multiple 
water  heater  installation,  each  water  heater  must  have  its 
own supply gas regulator. If required, the supply gas regulator 
shall be rated at or above the Btu/hr input rating of the water 
heater it supplies. If a supply gas regulator is installed on the 
gas supply line, the maximum recommended pressure for the 
regulated gas supply is 11" W.C.
Supply  gas  regulators  shall  have  inlet  and  outlet  connections 
not  less  than  the  minimum  supply  gas  line  size  for  the  water 
heater they serve as shown in Table 9. The maxitrol 325-7L or 
equivalent is recommended.
power supply
The  water  heaters  covered  in  this  manual  require  a  120 
VAC,  1Ø  (single  phase),  60Hz,  15  amp  power  supply  and 
must also be electrically grounded in accordance with local 
codes or, in the absence of local codes, with the National 
electrical  Code, ANSI/NfPA  70  or  the  Canadian  electrical 
Code, CSA C22.1.
installation reQuirements