Chapter 4 - Operation 
32 
Standard Operation
 
This section describes the standard recommended procedure to follow when preparing 
to detect drives and mount drive’s volume in a write-protected environment using Super 
DriveLock unit. 
 
1.  Verify Installation 
 
  Verify that the Super DriveLock and PC/Notebook are properly configured using 
the Installation instructions listed i
. 
 
2.  Prepare the Drive for Detection and Mounting 
 
  Verify that the Suspect’s drive jumper block is properly configured. 
 
 
For P-ATA drives the jumper block should be set for “Single/Master” operation.  
For SCSI drives the SCSI Address jumper block should be set to 0. 
 
  Using the supplied data and power cable(s), connect the drive to the SDL’s 
appropriately labeled interface connector.  Connectors are available for P-ATA, 
S-ATA, SCSI and USB devices.  Refer t
 for a graphical 
display of drive positions. 
 
  For P-ATA data cables, connect the cable’s “HDD Side” labeled connector to the 
drive’s data connector.  Verify that the cable’s Pin-1 is properly oriented.  The 
cable’s Pin-1 should be aligned adjacent to the drive’s power connector  
(See Fig. 23). 
 
  For SCSI data cables, connect the ICS supplied single channel SCSI cable to the 
unit’s SCSI data connector.  Verify that the SCSI Cable Terminator is connected 
to the cable’s end connector.  The terminated connector is located on the drive 
side (See Fig. 24). 
 
NOTE:  A short and long S-ATA and P-ATA data and power cable set is provided 
for ease of use.