TECHNICAL DATA
FOUNDA
TION
Enclosure
Part
Number
Description
HK7800000S-EU1
w
19"h42U(1956)d750
rack
mount
enclosure
/
Plexiglas
Front
&
Sheetmetal
Sheetmetal
Rear
Doors
/
Side
Panels
HK7800000S-EU1S
w19"h42U(1956)d750
rack
mount
enclosure
/
Plexiglas
Front
&
Sheetmetal
Sheetmetal
Rear
Doors
/
No
Side
Panels
HK7880000S-EU1
w
19"h42U(1956)d953
rack
mount
enclosure
/
Plexiglas
Front
&
Sheetmetal
Sheetmetal
Rear
Doors
/
Side
Panels
HK7880000S-EU1S
w19"h42U(1956)d953
rack
mount
enclosure
/
Plexiglas
Front
&
Sheetmetal
Sheetmetal
Rear
Doors
/
No
Side
Panels
HK7880000SPEU1
w
19"h42U(1956)d953
rack
mount
enclosure
/
Perforated
Front
&
Rear
Rear
Doors
/
Side
Panels
HK7880000SPEU1S
w19"h42U(1956)d953
rack
mount
enclosure
/
Perforated
Front
&
Rear
Rear
Doors
/
No
Side
Panels
FOUNDA
TION
MCR
(Mini
Computer
Room)
Part
Number
Description
HD788CC00S-EU1
(w19"h42U(1956)d953
rack
mount
sealed
enclosure,
ECM2000LR,
BCM2000L,
No
UPS)
HD7880000S-EU1
(w19"h42U(1956)d953
rack
mount
sealed
enclosure,
ECM
Cluster
Extension
Duct,
NO
Side
Panels)
ENCLOSURE
DIMENSIONS
Model
Overall
Frame
Dimensions
Rack
Adjustable
Rack
Depth
Internal
Rack
Height
Height*
Width**
Depth***
Width
A
vailable
Width
B****
In.
(mm)
In.
(mm)
In.
(mm)
Max
In.
(mm)
Rack
U
In.
(mm)
H_780
77
(1956)
23.5
(597)
29.5
(750)
19
(483)
17.8
(450)
22.5
(571.5)
42
73.5
(1867)
H_788
77
(1956)
23.5
(597)
37.5
(953)
19
(483)
17.8
(450)
30.5
(775)
42
73.5
(1867)
*Casters
add
1,5"
to
overall
overall
Height
of
Frame
Frame
=
2000mm
**
Side
Side
Panels
add
0,75"
each
to
overall
overall
width
of
frame
frame
***
Doors
add
0,25"
each
to
overall
overall
depth
of
frame,
frame,
BCM
Option
adds
an
additional
3"
to
overall
to
overall
depth
of
frame
frame
****
Max
Dimension
is
for
for
ex-factory
configuration.
Rails
can
be
inverted
to
provide
provide
an
additional
4"
of
adjustment
of
adjustment
Mounting
Options
Enclosure/MCR
Fixed
Shelf
w19”d30”/38”
Pullout
Shelf
d30"/38"
Fixed
Rails
Keyboard
T
ray
Mounting
Clipnuts
and
Screws
10
-
32
Thread
M6
Thread
H_780
153018G1L
153009G1L
201
193G1L
155942G1
201000G1
201000G2
H_788
153018G1L
153009G3L
201
193G1L
155942G2
201000G1
201000G2
General
Options
Enclosure/MCR
Internal
Light
Sealed
Entrance
Cable
Rings
Cluster
Kit
Stabilisation
Plate
2"
hole
hole
4"
hole
hole
V
ertical
Horizontal
H_780,
H_788
163527G3
201038G1L
201038G2L
201048G1L
201049P1
201033G1L
201067G1L
Monitoring
Options
H_780,
H_788
SITENET
-EX230
LCM-IEC-10
163787G2L
163784G1L
168605G1L
163785G1L
163520G1L
163786G1L
163786G1L
All
monitoring
options
can
be
field
installed
(including
installation
instructions
and/or
drawings/sketches
as
required)
required)
*Alarm
is
powered
powered
by
either
either
the
ECM
or
BCM
BCM
-
if
neither
ECM
or
BCM
BCM
is
available
available
a
Power
Supply
option
must
be
selected
Cooling
Options
Enclosure/MCR
F
AN
Cooling
Systems
ECM
Cooling
System
F
AN
1000
Low
Noise
50Hz
F
AN
1000H
High
Ambient
50Hz
F
AN
Block-of
f
Assembly
50Hz
ECM
Heat
Rejection
Fan
50Hz
Top
Mount
Mount
ECM
for
1000
1000
V
A
UPS
*
Top
Mount
Mount
ECM
for
1000
1000
V
A
UPS
*
HK780,
HK788
163796G2L
163796G4L
201592G1L
163521P2
168124G6
168124G8
HD788
-
-
-
163521P2
168124G6
168124G9
*Requires
Stabilizing
Plate
option
(201067G1L)
P
ART
NUMBERS
AND
CONFIGURA
TIONS
LISTED
ABOVE
ARE
A
V
AILABLE
DIRECTL
Y
FROM
ST
OCK
OCK
-
MORE
OPTIONS
AND
CONFIGURA
TIONS
ARE
ALSO
A
V
AILA
BLE
ON
DEMAND,
PLEASE
REFER
T
O
YOUR
LIEBERT
-HIROSS
CONT
ACT
Enclosure/MCR
SiteNet
Integrator
Load
Control
Module
(SiteNet
Interface
Only)
Internal
T
emp/Humid
Opt.
(SiteNet
Interface
Only)
External
Temperature/Humid
Opt.
(SiteNet
Interface
Only)
Door
Ajar
Sensor
Opt.
(
SiteNet
Interface)
High
T
emperature
Alarm*
W
ater
Detected
Opt.*
Power
Supply
for
High
T
emp.
&
W
W
ater
Detect.
Option
Smoke
Detector
Opt.
(requires
High
Temperature
Alarm
Option)