TECHNICAL DATA
FOUNDA
TION 
Enclosure
Part 
Number
Description
HK7800000S-EU1 
w
19"h42U(1956)d750 
rack 
mount 
enclosure 
Plexiglas 
Front 

Sheetmetal 
Rear 
Doors 
Side 
Panels
HK7800000S-EU1S 
w19"h42U(1956)d750 
rack 
mount 
enclosure 
Plexiglas 
Front 

Sheetmetal 
Rear 
Doors 
No 
Side 
Panels
HK7880000S-EU1 
w
19"h42U(1956)d953 
rack 
mount 
enclosure 
Plexiglas 
Front 

Sheetmetal 
Rear 
Doors 
Side 
Panels
HK7880000S-EU1S 
w19"h42U(1956)d953 
rack 
mount 
enclosure 
Plexiglas 
Front 

Sheetmetal 
Rear 
Doors 
No 
Side 
Panels
HK7880000SPEU1 
w
19"h42U(1956)d953 
rack 
mount 
enclosure 
Perforated 
Front 

Rear 
Doors 
Side 
Panels
HK7880000SPEU1S 
w19"h42U(1956)d953 
rack 
mount 
enclosure 
Perforated 
Front 

Rear 
Doors 
No 
Side 
Panels
FOUNDA
TION 
MCR 
(Mini 
Computer 
Room)
Part 
Number
Description
HD788CC00S-EU1 
(w19"h42U(1956)d953 
 rack 
mount 
sealed 
enclosure, 
ECM2000LR, 
BCM2000L, 
No 
UPS)
HD7880000S-EU1 
(w19"h42U(1956)d953 
 rack 
mount 
sealed 
enclosure, 
ECM 
Cluster 
Extension 
Duct, 
NO 
Side 
Panels)
ENCLOSURE 
DIMENSIONS
Model
Overall 
Frame 
Dimensions
Rack
Adjustable 
Rack 
Depth
Internal 
Rack 
Height
Height*
Width**
Depth***
Width
A
vailable 
Width
B****
In. 
(mm)
In. 
(mm)
In. 
(mm)
Max 
In. 
(mm)
Rack 
U
In. 
(mm)
H_780
77 
(1956)
23.5 
(597)
29.5 
(750)
19 
(483)
17.8 
(450)
22.5 
(571.5)
42
73.5 
(1867)
H_788
77 
(1956)
23.5 
(597)
37.5 
(953)
19 
(483)
17.8 
(450)
30.5 
(775)
42
73.5 
(1867)
*Casters 
add 
1,5" 
to 
overall 
Height 
of 
Frame 
2000mm
** 
Side 
Panels 
add 
0,75" 
each 
to 
overall 
width 
of 
frame
*** 
Doors 
add 
0,25" 
each 
to 
overall 
depth 
of 
frame, 
BCM 
Option 
adds 
an 
additional 
3" 
to 
overall 
depth 
of 
frame
**** 
Max 
Dimension 
is 
for 
 ex-factory 
configuration. 
Rails 
can 
be 
inverted 
to 
provide 
an 
additional 
4" 
of 
adjustment
Mounting 
Options
Enclosure/MCR
Fixed 
Shelf 
w19”d30”/38”
Pullout 
Shelf 
d30"/38"
Fixed 
Rails
Keyboard 
T
ray
Mounting 
Clipnuts 
and 
Screws
10 
32 
Thread
M6 
Thread
H_780
153018G1L
153009G1L
201
193G1L
155942G1
201000G1
201000G2
H_788
153018G1L
153009G3L
201
193G1L
155942G2
201000G1
201000G2
General 
Options
Enclosure/MCR
Internal 
Light
Sealed 
Entrance
Cable 
Rings
Cluster 
Kit
Stabilisation 
Plate
2" 
hole
4" 
hole
V
ertical
Horizontal
H_780, 
H_788
163527G3
201038G1L
201038G2L
201048G1L
201049P1
201033G1L
201067G1L
Monitoring 
Options
H_780, 
H_788
SITENET
-EX230
LCM-IEC-10
163787G2L
163784G1L
168605G1L
163785G1L
163520G1L
163786G1L
163786G1L
All 
monitoring 
options 
can 
be 
field 
installed 
(including 
installation 
instructions 
and/or 
drawings/sketches 
as 
required)
*Alarm 
is 
powered 
by 
either 
the 
ECM 
or 
BCM 
if 
neither 
ECM 
or 
BCM 
is 
available 
Power 
Supply 
option 
must 
be 
selected
Cooling 
Options
Enclosure/MCR
F
AN 
Cooling 
Systems
ECM 
Cooling 
System
F
AN 
1000 
Low 
Noise 
50Hz
F
AN 
1000H 
High 
Ambient 
50Hz
F
AN 
Block-of
Assembly 
50Hz
ECM 
Heat 
Rejection 
Fan 
50Hz
Top 
Mount 
ECM 
for 
1000 
V
A
UPS 
*
Top 
Mount 
ECM 
for 
1000 
V
A
UPS 
*
HK780, 
HK788
163796G2L
163796G4L
201592G1L
163521P2
168124G6
168124G8
HD788
-
-
-
163521P2
168124G6
168124G9
*Requires 
Stabilizing 
Plate 
option 
(201067G1L) 
P
ART 
NUMBERS 
AND 
CONFIGURA
TIONS 
LISTED 
ABOVE 
ARE 
A
V
AILABLE 
DIRECTL
Y
FROM 
ST
OCK 
MORE 
OPTIONS 
AND 
CONFIGURA
TIONS 
ARE 
ALSO 
A
V
AILA
BLE 
ON 
DEMAND, 
PLEASE 
REFER 
T
O
 YOUR 
LIEBERT
-HIROSS 
CONT
ACT
Enclosure/MCR
SiteNet 
Integrator
Load 
Control 
Module
(SiteNet
Interface 
Only)
Internal 
T
emp/Humid
Opt. 
(SiteNet
Interface 
Only)
External
Temperature/Humid 
Opt.
(SiteNet 
Interface 
Only)
Door 
Ajar 
Sensor
Opt. 
SiteNet 
Interface)
High 
T
emperature
Alarm*
W
ater
Detected 
Opt.*
Power 
Supply 
for
High 
T
emp. 

W
ater
Detect. 
Option
Smoke 
Detector 
Opt.
(requires 
High 
Temperature
Alarm 
Option)