Crucial Micron P300 200GB SATA MTFDDAC200SAL-1N1AA Manuale Utente
![Crucial](https://files.manualsbrain.com/attachments/6e195041f2d2c7f82ee3cff663acab44f76b1ca5/common/fit/150/50/3023e03f5bb0135755632caa4d71c4ac009d4f9262e06c2f32ab26e565e8/brand_logo.jpeg)
Codici prodotto
MTFDDAC200SAL-1N1AA
Table 6: IDENTIFY Device ID (Continued)
• F = The content of the word is fixed and does not change
• V = The content of the word is variable and may change depending on the state of the device or the commands execu-
• V = The content of the word is variable and may change depending on the state of the device or the commands execu-
ted by the device
• X = The fixed or variable type of this field is not defined in the governing standard
• R = The content of the word is reserved and shall be zero
• R = The content of the word is reserved and shall be zero
Word
Bit(s)
Setting
Default Value
Description
49
15–14
00b
Reserved for IDENTIFY PACKET DEVICE command
13
F
1b
1 = Standby timer values as specified in ATA-8 ACS-2 are
supported
0 = Standby timer values shall be managed by the device
supported
0 = Standby timer values shall be managed by the device
12
0b
Reserved for IDENTIFY PACKET DEVICE command
11
F
1b
1 = IORDY supported
0 = IORDY may be supported
0 = IORDY may be supported
10
F
1b
1 = IORDY may be disabled
9
F
1b
1 = Shall be set to 1 to indicate that LBA is supported
8
F
1b
1 = DMA support
7–2
X
00000000b
Reserved
1–0
00b
Current long physical sector alignment setting
50
15
F
0b
Shall be cleared to 0
14
F
1b
Shall be set to 1
13–2
00000000b
Reserved
1
X
0b
Obsolete
0
F
1b
Shall be set to 1 to indicate vendor-specific standby timer
value minimum
value minimum
51
X
0000h 0000h
Obsolete
53
15–8
F
00000000b
Free-fall control sensitivity
00h = Vendor's recommended setting
01h-FFh = Sensitivity level; a larger number is a more sensi-
tive setting
00h = Vendor's recommended setting
01h-FFh = Sensitivity level; a larger number is a more sensi-
tive setting
7–3
00000b
Reserved
2
F
1b
1 = The fields reported in word 88 are valid
0 = The fields reported in word 88 are not valid
0 = The fields reported in word 88 are not valid
1
F
1b
1 = The fields reported in words (70:64) are valid
0 = The fields reported in words (70:64) are not valid
0 = The fields reported in words (70:64) are not valid
0
X
1b
Obsolete
54
X
3FFh 0010h 003Fh
FC10h 00FBh
Obsolete
P300 2.5-Inch NAND Flash SSD
Device ID
PDF: 09005aef840793dc
p300_2_5.pdf - Rev. K 5/12 EN
p300_2_5.pdf - Rev. K 5/12 EN
8
Micron Technology, Inc. reserves the right to change products or specifications without notice.
©
2010 Micron Technology, Inc. All rights reserved.