Moxa ioLogik E1214 IOLOGIK E1214 Manuale Utente
Codici prodotto
IOLOGIK E1214
1
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Remote I/O
ioLogik E1200 Series
Ethernet remote I/O with 2-port Ethernet switches
Daisy-chained Ethernet I/O Connection
A new daisy-chained Ethernet I/O concept is now available. The ioLogik
E1200 industrial Ethernet remote I/O has two embedded Ethernet
switch ports that allow information to flow to another local Ethernet
device or connect to the next ioLogik in the daisy-chain. Applications
such as factory automation, security and surveillance systems, and
tunnel monitoring, can make use of daisy-chained Ethernet for building
multi-drop I/O networks over standard Ethernet cables. Many industrial
automation users are familiar with multi-drop as the configuration
E1200 industrial Ethernet remote I/O has two embedded Ethernet
switch ports that allow information to flow to another local Ethernet
device or connect to the next ioLogik in the daisy-chain. Applications
such as factory automation, security and surveillance systems, and
tunnel monitoring, can make use of daisy-chained Ethernet for building
multi-drop I/O networks over standard Ethernet cables. Many industrial
automation users are familiar with multi-drop as the configuration
typically used in fieldbus applications. The daisy-chain function on the
ioLogik E1200 Ethernet remote I/O not only increases the connections
between machines and panels, but also lowers the cost of buying
separate Ethernet switches, and at the same time reduces labor fees
and cabling by a large percentage. For example, if a production facility
contains 700 stations (20 points per station), the wiring cost reduction
can reach 15% of the total implementation cost.
ioLogik E1200 Ethernet remote I/O not only increases the connections
between machines and panels, but also lowers the cost of buying
separate Ethernet switches, and at the same time reduces labor fees
and cabling by a large percentage. For example, if a production facility
contains 700 stations (20 points per station), the wiring cost reduction
can reach 15% of the total implementation cost.
ioLogik E1200 Series Selection Table
Models
I/O Combinations
Digital Inputs
Digital Outputs
Analog Inputs
Analog Outputs
RTD Inputs
TC Inputs
Relay Outputs
Configurable
DIOs
ioLogik E1210
16
–
–
–
–
–
–
–
ioLogik E1211
–
16
–
–
–
–
–
–
ioLogik E1212
8
–
–
–
–
–
–
8
ioLogik E1213
8
4
–
–
–
–
–
4
ioLogik E1214
6
–
–
–
–
–
6
–
ioLogik E1240
–
–
8
–
–
–
–
–
ioLogik E1241
–
–
–
4
–
–
–
–
ioLogik E1242
4
–
4
–
–
–
–
4
ioLogik E1260
–
–
–
–
6
–
–
–
ioLogik E1262
–
–
–
–
–
8
–
–
Introduction
›
Active communication with patented Active OPC Server
›
2-port Ethernet switch for daisy-chain topologies
›
Easy mass deployment and configuration with ioSearch utility
›
Friendly configuration via web browser.
›
Save time and wiring cost with peer-to-peer communication
›
User-defined Modbus/TCP addressing
›
Simplify I/O management with MXIO library on either Windows or Linux platform
›
Wide operating temperature: -40 to 75°C (-40 to 167°F)
›
Supports SNMPv1/v2c
›
UL/cUL Class I Division 2, ATEX Zone 2 certifications