iStarUSA TC-750PD8 Manuale Utente
Page3
1.0 GENERAL REQUIREMENTS
This specification describes a 750 watts power supply. With 5 output, and remote
ON/OFF control for ATX-12V system and a “Power factor correction (active PFC)”
circuit at 100V-240Vac.
ON/OFF control for ATX-12V system and a “Power factor correction (active PFC)”
circuit at 100V-240Vac.
2.0 INPUT REQUIREMENTS
The AC mains steady-state input voltage shall be 100 to 240 Vrms
The power supply shall operate from 90 to 264 Vrms.
The power supply shall operate from an AC mains frequency of 47-63Hz.
The AC mains steady-state RMS input current shall be:
10 Amp (maximum) at 100-127Vrms/ 60 Hz
5Amp (maximum) at 200-240 Vrms/ 50 Hz.
.
The power supply shall operate from 90 to 264 Vrms.
The power supply shall operate from an AC mains frequency of 47-63Hz.
The AC mains steady-state RMS input current shall be:
10 Amp (maximum) at 100-127Vrms/ 60 Hz
5Amp (maximum) at 200-240 Vrms/ 50 Hz.
.
3.0 OUTPUT REQUIREMENTS
3.1 OUTPUT VOLTAGE AND CURRENT
MINIMUM
LOAD
NORMAL
LOAD
MAXIMUM
LOAD
LOAD
REG.
LINE
REG.
RIPPLE & NOISE
+3.3V
0.2A
10A
26/12A
±
5%
±
1%
50mV P-P
+5V
1A
9A
16.8/26A
±
5%
±
1%
50mV P-P
+12V
1A
24A
60A
±
5%
±
1%
120mV P-P
-12V
0A
0.25A
0.3A
±
10%
±
2%
200mV P-P
+5Vsb
0A
1A
3A
±
5%
±
1%
50mV P-P
+5Vsb peak current is 4A(less then 0.5S).
(1)
+3.3V & +5V total output not exceed 170W.
When
+5V is load to 26A, the +3.3V maximum load is 12A.
When
+3.3V is load to 26A, the +5V maximum load is 16.8A.
(2) All outputs shall be safety-isolated from the AC mains and share a common
return. This common return must be connected to supply chassis.
(3) Voltages and ripple are measured at the load side of mating connectors with a
0.1uF monolithic ceramic capacitor paralleled by a 10uF electrolytic capacitor
across the measuring terminals.
across the measuring terminals.