Finisar GBIC 1310nm 10km FTL-1319-3D Manuale Utente

Codici prodotto
FTL-1319-3D
Pagina di 9
FTL-1319-3D Long-Wavelength GBIC Specification – November 2007 
F i n i s a r
 
 
 
© Finisar Corporation November 16, 2007 Rev. C3   
Page 3 
 
 
 
II. 
Electrical Power Interface 
 
Finisar FTL-1319-3D GBICs have an extended power supply voltage range of 3.15 V to 
5.5 V as described in Table 2.  They are compatible with both 3.3V and 5 V systems. 
 
Parameter 
 
Symbol Min 
Typ Max Units 
Notes/Conditions 
Supply Current 
I
s
 200 300 mA 
 
Inrush Current 
I
surge
 
 
+30 
mA 
Hot plug, above steady 
state current.
 
Absolute Supply Voltage 
V
max
-0.3 
 
Not to be applied 
continuosly 
Operating Supply Voltage 
V
cc
3.15   5.5  V 
Referenced 
to 
GND 
Table 2. Electrical power interface 
 
III. Low 
Speed 
Signals 
 
RX_LOS and TX_DISABLE are TTL signals as described in Table 3.  MOD_DEF(1) 
(SCL) and MOD_DEF(2) (SDA), are open drain CMOS signals (see section VIII, “Serial 
Communication Protocol”).  Both MOD_DEF(1) and MOD_DEF(2) must be pulled up to 
host_Vcc.  For more detailed information, see sections 5.3.1 – 5.3.8 in the GBIC 
Specification Rev. 5.5
1
 
Parameter 
 
Symbol Min 
Max Units 
Notes/Conditions 
GBIC Output LOW 
V
OL
0.5 
4.7k to 10k pull-up to host_Vcc, 
measured at host side of connector 
GBIC Output HIGH 
V
OH
host_Vcc - 0.5 host_Vcc + 0.3
4.7k to 10k pull-up to host_Vcc, 
measured at host side of connector 
GBIC Input LOW 
V
IL
0.8 
4.7k to 10k pull-up to Vcc, 
measured at GBIC side of 
connector 
GBIC Input HIGH 
V
IH
Vcc + 0.3 
4.7k to 10k pull-up to Vcc, 
measured at GBIC side of 
connector 
Table 3. Low speed signals – electronic characteristics