VII.  Environmental Specifications 
 
Note that the GBIC Specification requires an ambient temperature range of 0 to 50°C.  
The FTL-1319-3D has an extended range from –10°C to +85°C case temperature as 
specified in Table 8.   
 
VIII.  Serial Communication Protocol 
Parameter 
 
Symbol Min  Typ  Max Units Notes/Conditions 
Operating Temp 
T
op
-10  85 °C 
Case 
Temperature 
Relative Humidity 
RH 
 
85 
Non Condensing 
Storage Temp 
T
sto
-40  85 °C 
Eye Safety 
-- 
 
 
 
 
CDRH and IEC-825 Class 1 Laser 
Product.  See Note 1 
Note 1: Complies with FDA performance standards for laser products except for deviations pursuant to 
Laser Notice No. 50, dated July 26, 2001. 
Table 8. Environmental specifications 
 
All Finisar optical GBICs implement serial identification features described for ‘Module 
Definition “4”’ as outlined in Annex D of the GBIC Specification
1
. These GBICs use an 
Atmel AT24C01A 128 byte E
2
PROM at address A0H.  For details on interfacing with the 
E
2
PROM, see the Atmel data sheet titled “AT24C01A/02/04/08/16 2-Wire Serial CMOS 
E
2
PROM.”
6
  
 
The FTL-1319-3D-DD also supports extended diagnostic features as described in Finisar 
Applications Note AN-2030, “Digital Diagnostic Monitoring Interface for Optical 
Transceivers”
8
, and additional information is available in SFF standard titled: “Digital 
Diagnostic Monitoring Interface for Optical Transceivers”
7
 (SFF-8472 rev9.3). A 
controller IC that monitors system parameters such as laser current, module temperature, 
transmitter power, and received power is accessible at address A2H. 
 
I2C clock speed, digital diagnostic accuracy and digital diagnostic range can be found in 
the table below.  Values in the table represent the worst-case values over temperature, 
voltage, and life.