Vigitron VB1001F Dépliant

Pagina di 2
© Copyright 2009 Vigitron, Inc.
1.20"
1.85"
0.54"
0.54"
VB1001M
Technical Specification**
  *It is recommended not to exceed 750 ft. (228 m) when using with digital equipment.
**Specifications are subject to change without notice.
Electrical
Video Format 
NTSC, PAL, SECAM
Frequency 
DC to 10 MHz
Coax 
75 Ohm
Twisted Pair  
100 Ohms +/- 20%, 24 AWG minimum
 
up to 1,000 ft. (305 m)* unshielded Category 2-7
Insertion Loss 
0.3 dB
CMRR 
60 dB 
Power 
No power required
Connectors 
Video: Male BNC 
 
UTP: Terminal block
Environmental
Humidity 
0 to 95%, non-condensing
Temperature  
Operating: -10°C to +50°C
 
Storage: -30°C to +70°C
Mechanical
Dimensions 
1.85x0.54 inches (47x13.6 mm)
Weight 
0.2 oz  (7 g)
Material 
ABS plastic, UL rating of 94V-0
TEL (+1) 858 - 484 - 5209 • FAX (+1) 858 - 484 - 1205  
13906 Sparren Ave.  San Diego, CA 92129, USA • info@vigitron.com • www.vigitron.com
Ordering Information
PART No.
Description
VB1001F                 Video Balun w/ 
Female BNC 
VB1001M                Video Balun w/ M
ale BNC 
System Configuration
1
Vi6100VR/Vi6200VR
4
Vi6104/Vi6204
8
Vi6108/Vi6208/Vi6308
16
Vi6116/Vi6216/Vi6316
32
Vi6132/Vi6232/Vi6332
Active Receivers
Channels
2,000 feet (610 m) for Vi6200 series
1
4
8
16  
32  
750 ft.
228 m 
Vi1004
Vi1008
Vi1016
Vi1032
VB1001F/M
VB1007M
Vi1001F/M/P
Vi1003M
Vi1006M
3,000 ft.
915 m 
Maximum Cable
Distance
Passive Transceivers
Model
Model
Channels
Wire and Cable Recommendations
The Vigitron products are designed to be used with unshielded twisted pair (UTP) wiring. The UTP wire must be 24AWG - 12AWG or Category 2-7 cable. 
Multi pair cable with an overall shield is acceptable, however individually shielded pairs should be avoided. Multiple UTP video feeds can be operated in 
the same communication cable along with telephone, computer, control signals and low power voltages. While UTP video may be routed through 
punch-down block terminals, any resistive, capacitive or inductive devices (such as T-taps or MOV's) must not be used.  Please contact Vigitron for more 