Toshiba RAS-107SKV-E4 Manuale Utente
Capacity control = Variable
TOSHIBA CARRIER (THAILAND) CO., LTD.
144/9 Moo 5, Bangkadi Industrial Park, Tivanon Road,
Tambol Bangkadi, Amphur Muang, Pathumthani 12000 THAILAND
Appliance - Split type air conditioner
Outdoor unit
Single Inverter
RAS-107SAV-E4
Indoor unit
Hi-wall - Avant
RAS-107SKV-E4
Function
Cooling
Y
Heating - Average
Y
Heating - Warmer
N
Heating - Colder
N
Design load
cooling
Pdesignc
2,0
kW
heating/Average
Pdesignh
2,8
kW
Seasonal efficiency
cooling
SEER
6,00
A+
heating/Average
SCOP(A)
3,90
A
Cooling
Capacity
Declared capacity for cooling at indoor temperature 27(19)°C and outdoor
temperature Tj
temperature Tj
Efficiency
Declared Energy efficieny ratio for cooling at indoor temperature 27(19)°C
and outdoor temperature Tj
and outdoor temperature Tj
Tj=35
℃
Pdc
2,00
kW
Tj=35
℃
EERd
3,73
Tj=30
℃
Pdc
1,47
kW
Tj=30
℃
EERd
6,76
Tj=25
℃
Pdc
1,56
kW
Tj=25
℃
EERd
9,20
Tj=20
℃
Pdc
1,84
kW
Tj=20
℃
EERd
12,72
Heating (Average climate)
Capacity
Declared capacity for heating/Average season, at indoor temperature 20 °C and
outdoor temperature Tj
outdoor temperature Tj
Efficiency
Declared coefficient of performance/Average season, at indoor
temperature 20 °C and outdoor temperature Tj
temperature 20 °C and outdoor temperature Tj
Tj=-7°C
Pdh
2,48
kW
Tj=-7°C
COPd
2,57
Tj=2°C
Pdh
1,51
kW
Tj=2°C
COPd
3,80
Tj=7°C
Pdh
0,97
kW
Tj=7°C
COPd
5,37
Tj=12°C
Pdh
1,25
kW
Tj=12°C
COPd
6,09
Tj=bivalent temperature
Pdh
2,48
kW
Tj=bivalent temperature
COPd
2,57
Tj=operation limit
Pdh
2,08
kW
Tj=operation limit
COPd
2,46
Bivalent temperature
-7
°C
Operation limit temperature
-10
°C
Electricity
Electric power input in power modes other than "on mode"
Seasonal electricity consumption
off mode
Poff
0,008
kW
cooling
QCE
117
kWh/a
standby mode
Psb
0,008
kW
heating/Average
QHE/A
1005
kWh/a
thermostat-off mode
Pto
0,037
kW
heating/Warmer
QHE/B
_
kWh/a
Page 1 of 2
05/03/2013
http://ecodesign.toshiba-airconditioning.eu/en/system-details?system=4d2b8312e37b4...