Cisco 16GB USB UCS-USBFLSHB-16GB= Manuale Utente

Codici prodotto
UCS-USBFLSHB-16GB=
Pagina di 68
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
TECHNICAL SPECIFICATIONS
67
Environmental Specifications
The power specifications for the C22 M3 server are listed in 
.
Table 36  UCS C22 M3 Environmental Specifications
Parameter
Minimum
Temperature operating
41 to 95° F (5 to 35° C) Maximum temperature is to be derated 
by 1 degree C for every 305 m (1000 ft.) of altitude above sea 
level
Temperature nonoperating
–40 to 149°F (–40 to 65°C)
Humidity (RH) nonoperating, 
non-condensing
10 to 90%
Altitude operating
0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating
0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure 
A-weighted per ISO7779 LWAd (Bels) 
Operation at 73°F (23°C) 
5.9
Sound Pressure level, Measure 
A-weighted per ISO7779 LpAm (dBA) 
Operation at 73°F (23°C) 
46