Axis 211M 0269-003 Manuale Utente

Codici prodotto
0269-003
Pagina di 48
AXIS 211M - I/O Terminal Connector 
 
34 
I/O Terminal Connector
The I/O terminal connector is used in applications such as motion detection, event triggering,
Pin 3
Pin 4
Pin 2
Pin 1
Terminal connector. Note that the pins 
are numbered 1-4, right to left.
 time 
lapse recording and alarm notifications. It provides the interface to: 
• 1 transistor output - For connecting external devices such as relays and LEDs. Con-
nected devices can be activated by AXIS VAPIX AP, output buttons on the Live View 
page or by an Event Type. The output will show as active (shown under Event Config-
uration > Port Status
) if the alarm device is activated.
• 1 digital input - An alarm input for connecting devices that can toggle between an 
open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, 
etc. When a signal is received the state changes and the input becomes active (shown 
under Event Configuration > Port Status).
• Auxiliary power and GND
GND
1
5V DC Power 
2
Can be used as an alternative power supply (7-20VDC) or to power 
auxiliary equipment  +5VDC (100mA).
Max load = 100mA
Digital Input
3
Connect to GND to activate, or leave floating (or unconnected) to 
deactivate.
Must not be exposed to voltages greater 
than  
20VDC
Transistor Output
4
Uses an open-collector NPN transistor with the emitter connected 
to the GND pin. If used with an external relay, a diode must be 
connected in parallel with the load, for protection against voltage 
transients.
Max load =100mA 
Max voltage = 24VDC  
(to the transistor)
Connection diagram
o
z
AXIS 211M
5V 
max. 100mA
e.g. pushbutton
4
o
3
o
o
2
1
Function Pin 
number
Notes
Specifications