4. First Aid Measures
Inhalation:
In case of excessive inhalation due to leaking batteries remove to fresh air. Obtain medical advice.
Skin contact:
If exposed to a leaking battery, remove contaminated clothing. Wash exposed areas with plenty of water and soap. If irritation
occurs, consult a physician.
Eye contact:
If a battery is leaking and materials contact eyes, flush immediately with running water for at least 15 minutes. Consult an
ophthalmologist at once.
Ingestion:
Not anticipated due to size of batteries. Choking may occur with the smaller size batteries. If exposed to a leaking battery,
rinse mouth and surrounding areas with running water for at least 15 minutes. Give plenty of water to drink, Do not induce
vomiting. Obtain medical advice.
5. Fire-fighting measures
Suitable extinguishing media:
Carbon dioxide (CO2), foam, dry chemical power.
Extinguishing media not to be used:
Never use a direct water jet.
Exposure hazards from combustion products:
In case of fire, Carbon dioxide, Carbon monoxide and toxic organic substances will be generated. Do not inhale fumes and
smoke.
Personal protective equipments:
Wear full protective clothing. Use self-contained apparatus.
6. Accidental release measures
Personal precautions:
Notify safety personal of large. Caustic potassium hydroxide may be released from leaking or ruptured batteries, Avoid eye or
skin contact and inhalation of vapours. Increase the ventilation. Wear protective clothing. Keep unprotected person away.
Environmental precautions:
Avoid discharge and penetration into sewerage systems, waterways, pits and cellars.
Methods for cleaning up:
Collect spilled material with an insert standard absorbent like sand or silica. Care for well-ventilated conditions. Recycle or