Conrad Energy AAA battery Lithium 1100 mAh 1.5 V 2 pc(s) 650554 Scheda Tecnica
Codici prodotto
650554
Title
Model
Description
Page
Product Specification LFB AAA
Lithium/Iron Disulfide (Li/FeS
2
)
2
5.2 Test Equipment
(1) Impedance meter
The impedance meter with AC 1kHz should be used
6.Test Procedure and Its Standard
Item
(1) Impedance meter
The impedance meter with AC 1kHz should be used
6.Test Procedure and Its Standard
Item
Measureing Procedure
Standard
6.1 Appearance
Visual
No Defect and Leak
6.2 Dimension
Caliper
As item 8
6.3 Weight
Scale
As item 3.12
6.4 Max.Discharge Current
1000mA
6.6 Open Circuit Voltage
Measure open circuit voltage
>1.72V
6.7 Internal Impedance
Measure the battery with 1kHz AC
6.8 Discharge Capacity
>1100mAh
6.9 Leakage Proof
The battery shall
No leakage should be
be stored at 40±2℃ and humidity
observed by visual
80±5%for 21 days
inspection
7.Discarging at 350mA and 100mA to 0.8V
8. Dimension(Bare cell) mm
Great Power Battery Co., Ltd
The battery discharge until final
discharge voltage 0.8V,at 0.2C and
measure the capacity
discharge voltage 0.8V,at 0.2C and
measure the capacity
Until final discharge voltage