Thermal Specifications
78
Dual-Core Intel® Xeon® Processor 5000 Series Datasheet
the system tries to enable On-Demand mode at the same time the TCC is engaged, the 
factory configured duty cycle of the TCC will override the duty cycle selected by the On-
Demand mode.
6.2.3
PROCHOT# Signal
An external signal, PROCHOT# (processor hot) is asserted when the processor die 
temperature has reached its factory configured trip point. If Thermal Monitor is enabled 
(note that Thermal Monitor must be enabled for the processor to be operating within 
specification), the TCC will be active when PROCHOT# is asserted. The processor can 
be configured to generate an interrupt upon the assertion or de-assertion of 
PROCHOT#. Refer to the Intel Architecture Software Developer’s Manual for specific 
register and programming details.
PROCHOT# is designed to assert at or a few degrees higher than maximum T
CASE
 (as 
specified by Thermal Profile A) when dissipating TDP power and cannot be interpreted 
as an indication of processor case temperature. This temperature delta accounts for 
processor package, lifetime and manufacturing variations and attempts to ensure the 
Thermal Control Circuit is not activated below maximum T
CASE
 when dissipating TDP 
power. There is no defined or fixed correlation between the PROCHOT# trip 
temperature, the case temperature or the thermal diode temperature. Thermal 
solutions must be designed to the processor specifications and cannot be adjusted 
based on experimental measurements of T
CASE
, PROCHOT#, or Tdiode on random 
processor samples.
6.2.4
FORCEPR# Signal
The FORCEPR# (force power reduction) input can be used by the platform to cause the 
Dual-Core Intel Xeon Processor 5000 series to activate the TCC. If the Thermal Monitor 
is enabled, the TCC will be activated upon the assertion of the FORCEPR# signal. 
Assertion of the FORCEPR# signal will activate TCC for both processor cores. The TCC 
will remain active until the system deasserts FORCEPR#. FORCEPR# is an 
asynchronous input. FORCEPR# can be used to thermally protect other system 
components. To use the VR as an example, when FORCEPR# is asserted, the TCC 
circuit in the processor will activate, reducing the current consumption of the processor 
and the corresponding temperature of the VR.
It should be noted that assertion of FORCEPR# does not automatically assert 
PROCHOT#. As mentioned previously, the PROCHOT# signal is asserted when a high 
temperature situation is detected. A minimum pulse width of 500 
µ
s is recommended 
when FORCEPR# is asserted by the system. Sustained activation of the FORCEPR# 
signal may cause noticeable platform performance degradation. Refer to the 
appropriate platform design guidelines for details on implementing the FORCEPR# 
signal feature.
6.2.5
THERMTRIP# Signal
Regardless of whether or not Thermal Monitor is enabled, in the event of a catastrophic 
cooling failure, the processor will automatically shut down when the silicon has reached 
an elevated temperature (refer to the THERMTRIP# definition in 
). At this 
point, the FSB signal THERMTRIP# will go active and stay active as described in 
. THERMTRIP# activation is independent of processor activity and does not 
generate any bus cycles. Intel also recommends the removal of V
TT
.