Amphenol AT04 6P Content: 1 pc(s) AT04 6P Guida Informativa
Codici prodotto
AT04 6P
13
www.sineco.com
1. Grasp crimped contact approx. one
inch behind the contact barrel.
2. Hold connector with rear grommet
facing you.
3. Push contact straight into receptacle
until a ‘click’ is felt. A slight tug will
confirm placement.
4. Insert wedge into receptacle.
3. Remove wedge.
2. Pull until wedge ‘pops’ out of
receptacle.
1. Remove wedge by inserting a hook
into an opening of the wedge.
5. A ‘click’ will be felt when the wedge is
fully installed.
Receptacle Assembly - Contact and Wedge Insertion
Receptacle Assembly - Contact and Wedge Removal
AT Series